Search
8 result(s) for RioChannelGroupConfigType
-
OPC-30142 – OPC UA for PROFINET Remote IORioChannelGroupConfigType The RioChannelGroupConfigType contains all configuration properties which are common to all RIO Channel configuration types. A Server may support an arbitrary subset of these properties. Each supported property applies ... shall be provided only if individual RIO Channel Objects are not provided. Table 20 - RioChannelGroupConfigType Definition Attribute Value BrowseName RioChannelGroupConfigType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype
-
OPC-30142 – OPC UA for PROFINET Remote IOdescription of the Variables of each individual VariableType refer to the definition of the RioChannelGroupConfigType in chapter 7.1.2 . This ObjectType contains all Variables defined by all RIO Channel configuration VariableTypes
-
OPC-30142 – OPC UA for PROFINET Remote IO11.4 HasRioConfigurationsemantic of this ReferenceType is to connect RioChannelGroup Objects with RioChannelGroupConfigType Objects . The HasRioConfiguration Reference is formally defined in Table 134 . Table 134 - HasRioConfiguration Definition Attributes Value BrowseName HasRioConfiguration InverseName
-
OPC-30142 – OPC UA for PROFINET Remote IO12.1 Conformance UnitsObjects contain bitmask and/or array Variables . Server PNRIO Configuration Channel Group Objects contain a RioChannelGroupConfigType Object . Server PNRIO Alarms Server supports diagnosis Alarms and Conditions . This includes support
-
OPC-30142 – OPC UA for PROFINET Remote IO12.2.2.3 PNRIO Base Server ProfileChannel Group Objects or any component of the later, as Process Variables or a RioChannelGroupConfigType Object . Table 138 - PNRIO Base Server Profile Group Conformance Unit / Profile Title Mandatory / Optional PNRIO
-
OPC-30142 – OPC UA for PROFINET Remote IO12.2.2.4 PNRIO Group Server ProfileProcess Variables Conformance Units . Servers implementing this Profile do not provide Channel Objects . Optionally RioChannelGroupConfigType Objects may be provided as components of Channel Group Objects . Table 139 - PNRIO Group Server
-
OPC-30142 – OPC UA for PROFINET Remote IOChannel Objects Conformance Units . Servers implementing this Profile do not provide Process Variables . Optionally RioChannelGroupConfigType Objects may be provided as components of Channel Group Objects . Table 140 - PNRIO Grouped Channels
-
OPC-30142 – OPC UA for PROFINET Remote IOChannel Groups, the PNRIO Channel Objects and the PNRIO Process Variables Conformance Units . Optionally RioChannelGroupConfigType Objects may be provided as components of Channel Group Objects . Table 141 - PNRIO Full Grouped