6 result(s) for RegularTimeToOperate
-
OPC-30141 – OPC UA for PROFIenergy8.1.4 EnergySavingModeTypeHasComponent Variable TimeMaxLengthOfStay 0:Duration 0:BaseDataVariableType M, RO 0:HasComponent Variable RegularTimeToOperate 0:Duration 0:BaseDataVariableType M, RO 0:HasComponent Variable ModePowerConsumption 0:Float 0:AnalogUnitType ... Variable shall contain the time of maximum stay in this Energy Saving Mode . The RegularTimeToOperate Variable shall contain the time value to reach "Ready to operate" (see Figure
-
OPC-30141 – OPC UA for PROFIenergy8.3.1 EnergyDevicePowerOffTypeTypeDefinition Other Subtype of the BaseObjectType defined in [OPC 10000-5] . 0:HasComponent Variable RegularTimeToOperate 0:Duration 0:BaseDataVariableType M, RO 0:HasComponent Variable TimeMinPause 0:Duration 0:BaseDataVariableType ... Information Model , the RepresentedBy Reference in the EnergyDevicePowerOffType Object is omitted. The RegularTimeToOperate Variable shall contain the time value to reach the state "Ready to operate
-
OPC-30141 – OPC UA for PROFIenergydestination Energy Saving Mode during and immediately after the transition. The relationship of RegularTimeToOperate and CurrentTimeToOperate during a mode transition shall follow the specification defined by PROFIenergy ... figure 14). xxxx Figure 12 - RegularTimeToOperate vs. CurrentTimeToOperate
-
OPC-34100 – OPC UA for Energy Consumption Management7.2.4 EnergySavingModeTypeHasComponent Variable TimeMaxLengthOfStay 0:Duration 0:BaseDataVariableType M, RO 0:HasComponent Variable RegularTimeToOperate 0:Duration 0:BaseDataVariableType M, RO 0:HasComponent Variable ModePowerConsumption 0:Float 0:AnalogUnitType ... Variable shall contain the time of maximum stay in this Energy Saving Mode . The RegularTimeToOperate Variable shall contain the time value to reach "Ready to operate" (see Figure
-
OPC-34100 – OPC UA for Energy Consumption Management7.3.1.1 OverviewNode Class BrowseName DataType TypeDefinition Other Subtype of the 0:BaseObjectType 0:HasComponent Variable RegularTimeToOperate 0:Duration 0:BaseDataVariableType M, RO 0:HasComponent Variable TimeMinPause 0:Duration 0:BaseDataVariableType ... HasComponent Method SwitchOffWOL M Conformance Units ECM Sleep Mode WOL The RegularTimeToOperate Variable shall contain the time value to reach the state "Ready to operate
-
OPC-34100 – OPC UA for Energy Consumption Managementdestination Energy Saving Mode during and immediately after the transition. The relationship of RegularTimeToOperate and CurrentTimeToOperate during a mode transition shall follow Figure 16 . A more comprehensive explanation ... found in PE 3802 . Figure 16 - RegularTimeToOperate vs. CurrentTimeToOperate