Search
12 result(s) for Position
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Locationdescribe relative spatial relationships another format or math might be needed to represent a position (e.g., in polar or cylindrical coordinates) or an orientation (e.g., in quaternion). Figure 25 shows ... SpatialLocationType ( 7.2 ) can be created. For example, a CartesianFrameQuaternionOrientationType , which can use the Variable Position in the same way the CartesianFrameAngleOrientationType uses it and describes Orientation with Quaternion
-
OPC-30020 – MDIS OPC UA Companion Specificationevery Node of the NodeClass , for example if an MDISValveObjectType defines a Mandatory item Position then every instance of the MDISValveObjectType must have an item Position available. Optional Objects have
-
OPC-30020 – MDIS OPC UA Companion SpecificationReferences Node Class BrowseName DataType TypeDefinition Other Subtype of the MDISBaseObjectType 0:HasComponent Variable Position ValvePositionEnum 0:BaseDataVariableType M, R 0:HasComponent Variable CommandRejected 0:Boolean 0:BaseDataVariableType ... Boolean reflects if the valve is available for control. The behaviour follows the MDISBaseObjectType. Position - This enumeration provides information about the current position of the valve (see section
-
OPC-30020 – MDIS OPC UA Companion Specification6.8.4 Valve Move Methodtime the Method returns to the Client . Therefore, the Client must monitor the Position of the valve to determine when the Move command actually finishes. The OverrideInterlocks , SEM , Signature
-
OPC-30020 – MDIS OPC UA Companion SpecificationAnalogItemType O, RO 0:HasComponent Method ResetTotalFlow See 6.9.9 O 0:HasComponent Variable Position 0:Float 0:BaseDataVariableType M, RO 0:HasComponent Variable TargetPosition 0:Float 0:BaseDataVariableType ... illustration. If the TotalFlow is provided then the ResetTotalFlow Method shall also be provided. Position - A Float that represents the current position in percent open for the CIMV. TargetPosition
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.6 SetPosition MethodSetPosition Method SetPosition Method is used to set a target position. Signature SetPosition ( [in] 0:Float Position, [in] SEMEnum SEM [in] 0:Boolean ShutdownRequest); Table 64 - SetPosition Method Arguments Argument ... Description Position Target position as percent of open. The CIMV will automatically maintain this position SEM The selection of which SEM to send the command to ShutdownRequest Boolean indicates that
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 ServerServer MDIS Valve Base Supports the base required aspect of the MDISValveObjectType . This includes position information and the Move Method for basic functionality. The Move Method basic functionality includes Direction ... Move Method ( ChokeMove Method ), Abort Method ( ChokeAbort Method ), The Move Method basic functionality includes Position , OverrideInterlocks and SEM . The SetCalculatedPosition Method basic functionality includes CalculatedPosition and if required the SetCalculatedPositionStatus
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.3 ClientMDIS Valve Client Base Uses the base required aspect of the MDISValveObjectType . This includes position information and the Move Method for basic functionality. The Move Method basic functionality includes Direction ... flag, the Move ( ChokeMoveMethod ), Abort ( ChokeAbortMethod ), SetCalculatedPosition ( ChokeSetCalculatedPositionMethod ). The Move Method basic functionality includes Position , OverrideInterlocks and SEM, The SetCalculatedPosition Method basic functionality includes CalculatedPosition and if required the SetCalculatePositionStatus
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basicsalways guaranteed. Table 151 - Example Samples list with conical tubes Array Index ContainerId SampleId Position CustomData 0 eB0000031725 S0815042 1 Sample 1 eB0000031726 S0815043 2 Sample .. .. .. .. .. 31 eB0000031856 S0815073 ... weights. It's important to highlight that the precise meanings and formats of the Position and CustomData properties fall beyond the scope of the LADS Companion Specification. However, forthcoming companion
-
OPC-40503-1 – OPC UA for Metal Forming - Part 1: GeneralLocation 0:HasProperty Variable Orientation String 0:PropertyType O 8:Location 0:HasComponent Variable Position Double 0:AnalogUnitRangeType O 8:Location 0:HasProperty Variable Stage UInt16 0:PropertyType ... Back" at bending machines) to align the tool at the tool holder. Position is a parameter which describes the absolute position of the central tool axis in dependency
-
OPC-40505 – OPC UA for Wireless Machine Tool Peripherals7.1.1 OverviewMeasurement WMTP Humidity Measurement WMTP Acceleration Measurement WMTP Force Measurement WMTP Torque Measurement WMTP Position Measurement WMTP Dimension Measurement WMTP WorkCycleData WMTP ServiceCycleData DeviceConfiguration is representing a collection ... Measurements 0:HasComponent Object <Torque> WMTPMeasurementType OP Measurements 0:HasComponent Object <Position> WMTPMeasurementType OP Measurements 0:HasComponent Object <Dimension> WMTPMeasurementType OP CalibrationMode indicates whether
-
OPC-40561-2 – OPC UA for Mining - Extraction - Part 2: Shearer Loader7.1.5 ObjectType Descriptionshield. The MaxLength variable indicates the maximum machine length including extracted drums. The Position variable indicates the current position of the Shearer Loader in relation to the center