3 result(s) for MinimumActualTime
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.12 MinimumActualTimeMinimumActualTime The MinimumActualTime Aggregate defined in Table 60 retrieves the minimum Good raw value within the interval, and returns that value with the timestamp at which that value occurs. Note ... oldest one is retrieved and the Aggregate Bits are set to MultipleValues. Table 60 - MinimumActualTime Aggregate summary MinimumActualTime Aggregate Characteristics Type Calculated Data Type Same as Source Use Bounds None
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.13 MaximumActualTimeMaximumActualTime The MaximumActualTime Aggregate defined in Table 61 is the same as the MinimumActualTime Aggregate , except that the value is the maximum raw value within the interval. Note that
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.17 MinimumActualTime2Table 65 retrieves the minimum Good value for each interval as defined for MinimumActualTime except that Simple Bounding Values are included. The Simple Bounding Values for the interval are found