Search
13 result(s) for InstrumentRange
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.3.2.2 BaseAnalogTypeHasSubtype VariableType AnalogItemType Defined in 5.3.2.3 HasSubtype VariableType AnalogUnitType Defined in 5.3.2.4 HasProperty Variable InstrumentRange Range PropertyType Optional HasProperty Variable InstrumentNumberRange NumberRange PropertyType Optional HasProperty Variable EURange Range PropertyType Optional ... Value contains an array, the Properties shall apply to all elements in the array. InstrumentRange defines the value range that can be returned by the instrument. EXAMPLE 1: InstrumentRange
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.3.4.1 GeneralHasSubtype VariableType CubeItemType Defined in 5.3.4.5 HasSubtype VariableType NDimensionArrayItemType Defined in 5.3.4.6 HasProperty Variable InstrumentRange Range PropertyType Optional HasProperty Variable EURange Range PropertyType Mandatory HasProperty Variable EngineeringUnits EUInformation PropertyType Mandatory ... LocalizedText PropertyType Mandatory HasProperty Variable AxisScaleType AxisScaleEnumeration PropertyType Mandatory Conformance Units Data Access ArrayItem2Type InstrumentRange defines the range of the Value of the ArrayItem. EURange defines the value range
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.4.2.3 Variable NodesRange ( Property ID: 104): if the node in the OPC UA Server references an InstrumentRange property node, then the 'High' value of the property node is assigned to this property ... Range ( Property ID: 105): if the node in the OPC UA Server references an InstrumentRange property node, then the 'Low' value of the property node is assigned to this property
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accesspercentage of Value . PERCENT_OF_RANGE 2 ExceptionDeviation is a percentage of InstrumentRange ( InstrumentRange is defined in OPC 10000-8 ). PERCENT_OF_EU_RANGE 3 ExceptionDeviation is a percentage
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.4.3.1 Variable Present_Valuedefined in OPC 10000-8 . It defines the OPC UA Properties EURange , EngineeringUnits and InstrumentRange . The following list provides the BACnet property and the mapping to the corresponding data member
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.18.3.1 Variable Present_Valuedefined in OPC 10000-8 . It defines the OPC UA Properties EURange , EngineeringUnits and InstrumentRange . The following list provides the BACnet property and the mapping to the corresponding data member
-
OPC-30142 – OPC UA for PROFINET Remote IODataValue Variable shall be provided only if the EngineeringUnits property is provided. The optional InstrumentRange and ValuePrecision Properties of the DataValue Variable may be provided if possible and meaningful. This
-
OPC-30142 – OPC UA for PROFINET Remote IODataValue Variable shall be provided only if the EngineeringUnits property is provided. The optional InstrumentRange and ValuePrecision Properties of the DataValue Variable may be provided if possible and meaningful. This
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drivescontains a temperature value provided by the Server . The Server might provide the optional InstrumentRange and EURange Properties of the 0:AnalogUnitType the TemperatureVariableType is derived from. The WarningThreshold Property
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process Valueswith key InstanceDeclarations . The 3: AnalogSignalVariableType provides the optional Properties 0: ValuePrecision and 0: InstrumentRange and the mandatory Properties 0: EURange and 0:EngineeringUnits and are used as defined
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process Valuesalready provides the mandatory 0: EURange , 0: EngineeringUnits and the optional 0: ValuePrecision , 0: InstrumentRange , 3: ActualValue , 3: SimulationValue and 3: SimulationState as defined ... have the same Value as the 0: EngineeringUnits Property of 3: AnalogSignal. The 0: InstrumentRange Property , if provided, shall have the same Value as the 0: InstrumentRange Property
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process Valueshigher low value. Instances of that VariableType shall not provide the 0: InstrumentRange . A process value setpoint Variable does not require the server to execute any internal logic to bring
-
OPC-40200 – OPC UA for Weighing TechnologyWeightItemType or a PrintableWeightItemType it is the range of net, gross and tare. InstrumentRange is specified like the EURange of the 0:AnalogItemType