Search
9 result(s) for Halted
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.2.3 Halting the systemwhich will need to be properly closed before shutting down that system. In Halted state, the system shall have put all resources into a state where it is safe ... However, not all operation is stopped, because the system can be brought out of Halted state by a call to the Reset method, transitioning to the Preoperational state. The vision
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.2.4 Error handlingfollowing ways: By a call to the Halt or Reset method, transitioning to states Halted and Preoperational respectively. The condition(s) causing the Error state do not necessarily have ... shall be triggered. By an internal decision of the system to transition into the Halted or Preoperational states. As these states do not constitute normal productive operation of the system
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.6.2 Preoperational Statereached, either by an automatic transition or by calling the Halt method for the Halted state or the SelectModeAutomatic method for sub-state Initialized of the Automatic mode SubStateMachine
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.6.4 Error Stateother state, or into Preoperational state by a Reset method call or into Halted state by a Halt method call, provided the requirements on Acknowledgement and Confirmation have been fulfilled
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.8.1 Halt methodHalt method This method commands the system to go into the Halted state from where it is safe to power down the system without damage to system resources (like files
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.2 Initialized Statemethod call. Into Preoperational state of the VisionStateMachine by a Reset method call. Into Halted state of the VisionStateMachine by a Halt method call. Into Error state of the VisionStateMachine
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.3 Ready StateInto the Preoperational state of the VisionStateMachine by a Reset method call. Into the Halted state of the VisionStateMachine by a Halt method call. Into the Error state
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.4 SingleExecution StateInto the Preoperational state of the VisionStateMachine by a Reset method call. Into the Halted state of the VisionStateMachine by a Halt method call. Into the Error state
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.5 ContinuousExecution StateInto the Preoperational state of the VisionStateMachineType by a Reset method call. Into the Halted state of the VisionStateMachineType by a Halt method call. Into the Error state