Search
14 result(s) for Halt
-
OPC-10000-10 – OPC Unified Architecture - Part 10: ProgramsTrue ProgramTransitionEventType HasEffect True AuditProgramTransitionEventType RunningToHalted ToState True Halted FromState True Running HasCause True Halt HasEffect True ProgramTransitionEventType HasEffect True AuditProgramTransitionEventType RunningToReady ToState True Ready FromState True Running HasEffect True ... True ProgramTransitionEventType HasEffect True AuditProgramTransitionEventType SuspendedToHalted ToState True Halted FromState True Suspended HasCause True Halt HasEffect True ProgramTransitionEventType HasEffect True AuditProgramTransitionEventType SuspendedToReady ToState True Ready FromState True Suspended HasCause True
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.4.1 OverviewOptional HasProperty OutputArguments PropertyType Optional Resume HasProperty InputArguments PropertyType Optional HasProperty OutputArguments PropertyType Optional Halt HasProperty InputArguments PropertyType Optional HasProperty OutputArguments PropertyType Optional Reset HasProperty InputArguments PropertyType Optional HasProperty OutputArguments ... causes the RunningToSuspended Program transition. The Resume Method causes the SuspendedToRunning Program transition. The Halt Method causes the RunningToHalted, SuspendedToHalted, or ReadyToHalted Program transition depending on the current state
-
OPC-10000-10 – OPC Unified Architecture - Part 10: ProgramsA.2.4.1 Generalstandard Program Methods are specified for running the DomainDownload Program, Start, Suspend, Resume, and Halt. No additional Methods are specified . The base behaviours of these Methods are defined ... pause the activity temporarily. The Resume Method reinitiates the download, when paused. The Halt Method aborts the download. Each of the Methods causes a Program state transition and a substate
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.2.3 Halting the systemdecide to enter Halted state due to internal conditions or by calling the Halt method on the OPC UA server. The Halt method shall always be executable. If for some
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.2.4 Error handlingError state can be left in the following ways: By a call to the Halt or Reset method, transitioning to states Halted and Preoperational respectively. The condition(s) causing
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.6.2 Preoperational Statethis level can be reached, either by an automatic transition or by calling the Halt method for the Halted state or the SelectModeAutomatic method for sub-state Initialized
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.6.3 Halted Statereached from any other state either by an automatic transition or by calling the Halt method. Calling the Halt method in this state will not have an effect. From this
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.8.1 Halt methodHalt method This method commands the system to go into the Halted state from where it is safe to power down the system without damage to system resources (like files ... takes, is application-defined and may depend on the parameter given to the Halt method (e.g. to distinguish between a fast shutdown due to power-loss or a more gentle
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result managementcontrast to an error or the complete stopping of operations by Reset and Halt methods. The difference between the two methods is: In response to an Abort method call
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.2 Initialized StateVisionStateMachine by a Reset method call. Into Halted state of the VisionStateMachine by a Halt method call. Into Error state of the VisionStateMachine by an internal error. All method-triggered
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.3 Ready StateReset method call. Into the Halted state of the VisionStateMachine by a Halt method call. Into the Error state of the VisionStateMachine by an internal error. All method-triggered transitions
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.4 SingleExecution StateReset method call. Into the Halted state of the VisionStateMachine by a Halt method call. Into the Error state of the VisionStateMachine by an internal error. All method-triggered transitions
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.5 ContinuousExecution StateReset method call. Into the Halted state of the VisionStateMachineType by a Halt method call. Into the Error state of the VisionStateMachineType by an internal error. All method-triggered transitions
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.4.1.4 Leaving the superior stateinternal causes (like error conditions) or external causes (like the Stop , Abort , Halt , Reset method calls). In that case, the SubStateMachine becomes inactive and will be in state Bad_StateNotActive