Search
8 result(s) for ErrorCode
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model6.3 BaseLogEventTypeOther Subtype of the 0:BaseEventType defined in OPC 10000-5 . 0:HasProperty Variable ErrorCode 0:StatusCode 0:PropertyType O 0:HasProperty Variable ErrorCodeNode 0:NodeId 0:PropertyType ... Event may be generated for propagation of this Event to a n external LogObject. ErrorCode is associated with the status related to the Node generating the LogRecord
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.3.2 Establishing Connectionsthat was passed in in the Call. In the case of an error, the ErrorCode shall contain the detailed error code returned in the EstablishConnections Method . This may result
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelshall include the FxErrorEnum value reported in the ConnectionDiagnosticsDataType associated with this error. ErrorCode shall contain the detailed error code returned in the nested return parameters of the EstablishConnection method ... Event being mapped to LogObject records. If the LogObject is recording LogRecords , the ErrorCode and the ErrorCodeNode shall be included in the resulting LogRecord as AdditionalData
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelshall include the FxErrorEnum value reported in the ConnectionDiagnosticsDataType associated with this error. ErrorCode shall contain the detailed error code returned in the Close Connection Method. ErrorCodeNode shall contain ... Event being mapped to LogObject records. If the LogObject is recording LogRecords , the ErrorCode and the ErrorCodeNode shall be included in the resulting LogRecord as AdditionalData
-
OPC-30001 – OPC UA Client Function Blocks for IEC 61131-3PLCopen or Vendor. Field Bit Range Description Severity 30:31 Indicates whether the ErrorCode represents a good, bad or uncertain condition. These bits have the following meanings: Good success ... cannot be used. Reserved 11 Reserved for future use. All Clients should treat an ErrorCode with this severity as "Bad". ErrorType 29 Value 0 indicates OPC error. Please
-
OPC-40210 – OPC UA for Geometric Measurement Systemswhich means it inherits the InstanceDeclarations of that Node. 0:HasProperty Variable ErrorCode 0:String 0:PropertyType 0:Mandatory Conformance Units GMS SensorWarningEventType The ErrorCode is used as the manufacturer
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: BaseHasComponent Variable ErrorTimestamp 0:UtcTime 0:BaseDataVariableType O, RO Health 0:HasComponent Variable ErrorCode 0:Int64 0:BaseDataVariableType O, RO Health 0:HasComponent Variable Temperature 0:Double JoiningDataVariableType ... ErrorTimestamp 0:UtcTime 0:BaseDataVariableType O, RO 4:Monitoring 4:Health 0:HasComponent Variable ErrorCode 0:Int64 0:BaseDataVariableType O, RO 4:Monitoring 4:Health 0:HasComponent Variable Temperature
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management9.1 AlertTypewhich means it inherits the InstanceDeclarations of that Node. 0:HasProperty Variable ErrorCode 0:String 0:PropertyType M, RO Conformance Units MachineTool Notification - Errors and Alerts The ErrorCode is used