OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.2.2 ParametersReadValueId Identifies an item in the AddressSpace to monitor. To monitor for Events , the attributeId element of the ReadValueId structure is the id of the EventNotifier Attribute . The ReadValueId type
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.7.4.4 AttributeOperandNode identified by the nodeId parameter. See 7.30 for the definition of RelativePath . attributeId IntegerId Id of the Attribute . This shall be a valid AttributeId . The IntegerId is defined
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.22.3 EventFilterresult code. The node specified by the browse path will never allow the given AttributeId to be returned. Bad_IndexRangeInvalid See Table 179 for the description of this result code
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.24.10 GenericAttributes parameterdescription of this Attribute . attributeValues GenericAttributeValue [] Defines one attributeId and value combination. attributeId IntegerId Id of the Attribute specified. AttributeIds shall be unique in the list and shall not repeat
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.25 AuditWriteUpdateEventTypedefined in 6.4.24 , which means it inherits the InstanceDeclarations of that Node. HasProperty Variable AttributeId UInt32 PropertyType Mandatory HasProperty Variable IndexRange NumericRange PropertyType Mandatory HasProperty Variable NewValue BaseDataType PropertyType Mandatory ... this type shall be "Attribute/Write". Their semantic is defined in 6.4.24 . AttributeId identifies the Attribute that was written. The SourceNode Property identifies the Node that was written. IndexRange
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.10.2.3 FieldTargetDataTypeNodeId of the Variable to which the received DataSetMessage field value is written. AttributeId IntegerId Id of the Attribute to write e.g. the Value Attribute . This shall be a valid ... AttributeId . The Attributes are defined in OPC 10000-3 . The IntegerId DataType is defined in OPC 10000-4 . The IntegerIds for the Attributes are defined in OPC 10000-6 . WriteIndexRange
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.8.5 CreateTargetVariables Methoddescription of this result code. This status code is related to the AttributeId . Bad_NoMatch This status code indicates that the DataSetFieldId is invalid. Bad_IndexRangeInvalid
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineeringboolean AML attributes; builtinType values are defined as string and not as integer; AttributeId values are defined as string and not as integer. When creating a NodeSet from