Search
13 result(s) for 0:RepresentsSameEntityAs
-
OPC-30142 – OPC UA for PROFINET Remote IObyte offset of the signal from the start of the binary telegram. The 0:RepresentsSameEntityAs Reference connects PnIoSignalType Objects with the "ProcessValue" Variables containing the Process Value provided
-
OPC-30142 – OPC UA for PROFINET Remote IOInput Channels "AI_1" and "AI_2" using a 0:RepresentsSameEntityAs Reference . The PnIoSignalType Objects ... Values they belong to connect to the "QualifierValue" Variables also using a 0:RepresentsSameEntityAs Reference . The direct connection of Signal Objects representing status data and qualifier Variables using
-
OPC-30142 – OPC UA for PROFINET Remote IOValue" are connected to the Process Value Variables with 0:RepresentsSameEntityAs References in the same way as described before. The qualifiers of RIO Output Channels according to RIOforFA ... OutputImageQualifiers" Variable in the functional aspect of the Information Model using a 0:RepresentsSameEntityAs Reference . The "SM1" PROFINET submodule Object connects to the RioFaAnalogChannelGroupType Object using
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.1 RioChannelGroupTypeaggregated RIO Channel Objects. The used cross-aspect ReferenceType s 0:RepresentsSameFunctionalityAs and 0:RepresentsSameEntityAs (see below) can only exist if the Server provides the PROFINET aspect of the Information ... Channel Group Object shall be linked to the associated PN Submodule using a 0:RepresentsSameFunctionalityAs Reference . The associated submodule addresses the same IO data as the Channel Group Object provides
-
OPC-30142 – OPC UA for PROFINET Remote IOVariables are linked to the associated PnIoSignalType Object in the PROFINET aspect using a 0:RepresentsSameEntityAs Reference
-
OPC-30142 – OPC UA for PROFINET Remote IOVariable is linked to the associated PnIoSignalType Object in the PROFINET aspect using a 0:RepresentsSameEntityAs Reference . RioPaAnalogProcessValueVariableType Variables are linked to the associated PnIoSignalType Object in the PROFINET aspect ... using a 0:RepresentsSameEntityAs Reference
-
OPC-30142 – OPC UA for PROFINET Remote IOVariables are linked to the associated PnIoSignalType Object in the PROFINET aspect using a 0:RepresentsSameEntityAs Reference
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>connected with components of the Encoder Objects in the functional aspect by dedicated 0:RepresentsSameEntityAs References . The EncoderChannelType serves as the root container for modelling of Encoder Objects . The functional ... same Signal , Variables of these two sub-aspects may also be connected using the 0:RepresentsSameEntityAs Reference type. The "Configuration" sub-aspect contains Objects holding configuration settings
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>linked to their Signal Variable counterpart in the "Signals" sub-aspect using 0:RepresentsSameEntityAs References . The "01_ZSW2_ENC", "02_G1_XIST1 ... linked to their counterpart Variables in the functional aspect of the Information Model using 0:RepresentsSameEntityAs References . The "ZSW2_ENC", "G1_XIST1" and "NIST
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>7.1.1 SetApplicationTag MethodXIST2, G1_XIST3) that are part of the configured Standard Telegram using a 0:RepresentsSameEntityAs Reference . The Velocity Variable contains the current Encoder's velocity encoded as 0:Float data ... Model , the Velocity Variable shall be linked to the source Signal Variable using a 0:RepresentsSameEntityAs Reference . The Acceleration Variable contains the currents Encoder's rate of velocity change encoded
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Modelaspect relate to components of the GsdGenIoDataType Objects in the functional aspect by dedicated 0:RepresentsSameEntityAs References . The components of the GsdGenSubmoduleApplicationType are separated into four sub-aspects as shown ... PROFIenergy model directly relates to the Submodule Object in the PROFINET Aspect using a 0:HasAddIn ReferenceType and has no connection with a GsdGenSubmoduleApplicationType Object
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model6.3 IO Datarelate to the Signal Objects representing IO Data in the PROFINET Aspect using a 0:RepresentsSameEntityAs ReferenceType . Figure 8 - XML Schema of Input and Output elements in GSDML
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drivesaspect relate to components of the Axis Objects in the functional aspect by dedicated 0:RepresentsSameEntityAs References (see Figure 10 ). Figure 10 - DriveAxisType Organization The Axis Objects serve ... Monitoring" folder, the Variables of these two sub-aspects are connected using the 0:RepresentsSameEntityAs ReferenceType (see Figure 11 ). Note, that Variables which are connected by the 0:RepresentsSameEntityAs