Search
21 result(s) for endTime
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessrequested. For a complete description of the Extensible Parameter HistoryReadDetails that include StartTime , EndTime and NumValuesPerNode, see 6.5 . The concept of Bounding Values and how they affect the time domain ... HistoryRead Service , the required parameters include at least two of these three parameters: startTime, endTime and numValuesPerNode . What is returned when BoundingValues are requested varies according to which of these
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical AccessHasProperty Variable IsDeleteModified Boolean PropertyType Mandatory HasProperty Variable StartTime UtcTime PropertyType Mandatory HasProperty Variable EndTime UtcTime PropertyType Mandatory HasProperty Variable OldValues DataValue[] PropertyType Mandatory ConformanceUnits Historical Access Audit Delete ... call. The StartTime reflects the starting time parameter of the call. The EndTime reflects the ending time parameter of the call. The OldValues identify the value that history contained before
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical AccessHasProperty Variable UpdatedNode NodeId PropertyType Mandatory HasProperty Variable StartTime UtcTime PropertyType Mandatory HasProperty Variable EndTime UtcTime PropertyType Mandatory ConformanceUnits Historical Access Audit BulkInsert Events This EventType inherits all Properties ... HistoricalEventNode . StartTime is the oldest time of the block that was inserted. EndTime is the newest time of the block that was inserted
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessperformed. Good_NoData is returned for cases such as: ReadEventDetails where startTime = endTime ReadEventDetails data is requested and does not exist ReadRawModifiedDetails where data is requested and does not exist
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessleast two of the three parameters, numValuesPerNode , startTime , and endTime shall be specified. Table 29 - ReadEventDetails Structure Name Type Description ReadEventDetails Structure Specifies the details used to perform an Event ... period to read. The default value of DateTime.MinValue indicates that the startTime is unspecified. endTime UtcTime End of period to read. The default value of DateTime.MinValue indicates that the endTime
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.2.2 Read Event functionalitycomplete description of filter refer to OPC 10000-4 . The startTime and endTime are used to filter on the Time field for Events . The time domain of the request ... defined by startTime , endTime , and numValuesPerNode; at least two of these shall be specified. If endTime is less than startTime , or endTime and numValuesPerNode alone are specified then the data
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessleast two of the three parameters, numValuesPerNode , startTime , and endTime shall be specified. Table 31 - ReadEventDetails2 Structure Name Type Description ReadEventDetails2 Structure Specifies the details used to perform an Event
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.2.4 Read modified functionalityfunction is to read Events from history that have been Modified. The startTime and endTime are used to filter on the Time field for Events . The domain of the request ... defined by startTime , endTime , and numValuesPerNode ; at least two of these shall be specified. If endTime is less than startTime , or endTime and numValuesPerNode alone are specified, then the data
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical AccessTable 35 defines the ReadRawModifiedDetails structure. Two of the three parameters, numValuesPerNode, startTime , and endTime shall be specified. Table 35 - ReadRawModifiedDetails structure Name Type Description ReadRawModifiedDetails Structure Specifies the details ... read. Set to default value of DateTime.MinValue if no specific start time is specified. endTime UtcTime End of period to read. Set to default value of DateTime.MinValue if no specific
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.3.2 Read raw functionalitydata on a display. The time domain of the request is defined by startTime , endTime , and numValuesPerNode ; at least two of these shall be specified. If endTime is less than ... startTime , or endTime and numValuesPerNode alone are specified then the data will be returned in reverse order, with later data coming first as if time were flowing backward. If numValuesPerNode
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.3.3 Read modified functionalityreturns a Bad_InvalidArgument StatusCode . The domain of the request is defined by startTime , endTime , and numValuesPerNode ; at least two of these shall be specified. If endTime is less than ... startTime , or endTime and numValuesPerNode alone are specified, then the data shall be returned in reverse order with the later data coming first. If all three are specified then
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.4.2 Read processed functionalitywhen ProcessingInterval is 1 hour. The domain of the request is defined by startTime , endTime , and ProcessingInterval . All three shall be specified. If endTime is less than startTime then ... returned in reverse order with the later data coming first. If startTime and endTime are the same then the Server shall return Bad_InvalidArgument as there is no meaningful
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical AccessDefault value is FALSE. startTime UtcTime Beginning of period to be deleted. endTime UtcTime End of period to be deleted. Its representation in the AddressSpace is defined in Table ... database, e.g., deletion of data from a source with incorrect timestamps. Both startTime and endTime shall be defined. The startTime shall be less than the endTime , and values
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates3.1.3 EffectiveEndTimeEffectiveEndTime time immediately before endTime Note 1 to entry: All Aggregate calculations include the startTime but exclude the endTime . However, it is sometimes necessary to return an Interpolated End Bound ... that is in the interval . Servers are expected to use the time immediately before endTime where the time resolution of the Server determines the exact value (do not confuse this
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates3.1.7 bounding valuesbounding values values at the startTime and endTime needed for Aggregates to compute the result Note 1 to entry: If Raw data does not exist at the startTime and endTime
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.2.4 Time calculation issuespart of the calculation. All Aggregate calculations include the startTime but exclude the endTime . However, it is sometimes necessary to return an Interpolated End Bound as the value ... that is in the Interval . Servers are expected to use the time immediately before endTime where the time resolution of the Server determines the exact value (do not confuse this
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.1 Generalallows Aggregates over large periods of time. A value with a timestamp equal to endTime will be excluded from that Aggregate , just as it would be excluded from an interval
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.3 DescriptionBounds. Timestamp What is the time stamp of the resulting Aggregate value: < startTime | endTime | Raw> startTime : The time at the start of the interval. endTime : The time
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.24 NumberOfTransitionsvalue exists or if the earliest non-Bad value is different. The endTime is not considered part of the interval, so a transition occurring at the endTime is not included
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.29 EndBoundEndBound Aggregate defined in Table 77 returns the value and status at the EndTime for the interval by calculating the Simple Bounding Values for the interval (see 3.1.9 ). The timestamp
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Modeldescribed in Table 2 . Signature GetRecords ( [in] 0:DateTime StartTime, [in] 0:DateTime EndTime, [in] 0:UInt32 MaxReturnRecords, [in] 0:UInt16 MinimumSeverity, [in] 0:LogRecordMask RequestMask, [in] 0:ByteString ContinuationPointIn ... first LogRecord returned will have the time closest to, but greater than StartTime . EndTime The time associated with the last LogRecord . EndTime must be equal to or greater than StartTime