Search
4 result(s) for Uses
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)10.1 Uses ReferenceTypeUses ReferenceType The Uses ReferenceType is a concrete ReferenceType and can be used directly. It is a subtype of the HasChild ReferenceType . The Uses reference indicates that a component ... filter aid, temperature regulator, cleaning system, air connection . Within a PAEFS model, the Uses reference should only connect the components outlined in Figure 6 . The Uses ReferenceType is formally defined
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)6.1 Model Overviewparts a PAEFS consists of and how they relate to each other. The representation uses a mixture of a type and instance representation for ease of understanding. Auxiliary objects that ... child node of the filter system and referenced by its filter units via the Uses reference defined in 10.1 . The shared component temperature regulator is intended to be referenced
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)cartridge filter. The assignment in the PAEFS data model is done via the Uses reference. The system also has several safety systems that are connected to the component ... monitored via a Uses reference. Figure 9 - Components installed in the air filtration system of example 2 Figure 10 - Formal representation of example
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)component in the PAEFS can reference an instance of the safety system via a Uses reference. It is formally defined in Table 50 . Table 50 - SafetySystemType Definition Attribute Value BrowseName