Search
3 result(s) for UpperTolerance2
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsUpperTolerance, LowerTolerance, UpperTolerance2, LowerTolerance2, MinValue, MaxValue These parameters are used to define limits for the monitored parameter. Exceeding the (relative) tolerance values creates a warning while exceeding the (absolute) Min/MaxValues ... switching off the heating, stopping of movements) as defined by the severity level. With UpperTolerance2 and LowerTolerance2 a second tolerance band can be defined. NOTE: When UpperTolerance and/or LowerTolerance
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions22.6 StatusABOVE_UPPER_TOLERANCE ActualValue is above UpperTolerance 7 ABOVE_UPPER_TOLERANCE2 ActualValue is above UpperTolerance2 8 ABOVE_MAX_VALUE ActualValue is above MinValue
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsNodeId of the element of the MonitoredParameterType which causes the error (e.g. UpperTolerance2 if this value is exceeded by the ActualValue