3 result(s) for StandbyTemperature
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devices9.6 OperatingModecarrying out a pressure relief process COOLING 6 TCD is cooling down to StandbyTemperature and switch off SAFETY_COOLING 7 TCD is cooling down to SwitchingOffTemperature and switch
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions17.2.9 StandbyTemperatureStandbyTemperature The StandbyTemperature Property represents the standby temperature of the Zone
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsHasComponent Object Temperature 6:ProcessValueType M 4:Monitoring 4:Process 0:HasComponent Object StandbyTemperature 6:ProcessValueType O 4:Monitoring 4:Process 0:HasComponent Object HeatingPower 6:ProcessValueType O 4:Monitoring ... material is heated. Temperature represents the temperature currently measured and or set. StandbyTemperature represents the temperature maintained in a standby mode of the heating system. HeatingPower represents the heating output