Search
5 result(s) for Speed
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network ModelHasComponent Variable OperStatus InterfaceOperStatus BaseDataVariableType Mandatory HasComponent Variable PhysAddress String BaseDataVariableType Optional HasComponent Variable Speed UInt64 AnalogUnitType Mandatory Conformance Units BNM Ethernet Base Info AdminStatus of DataType InterfaceAdminStatus specifies ... serial line), this node is not present (ifPhysAddress is defined in IETF RFC 2863 ). Speed of DataType UInt64 specifies an estimate of the network interface's current bandwidth in bits
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network ModelTypeDefinition Modelling Rule Subtype of the BaseInterfaceType defined in OPC 10000-5 HasComponent Variable Speed UInt64 AnalogUnitType Mandatory HasComponent Variable Duplex Duplex BaseDataVariableType Mandatory HasComponent Variable MaxFrameLength UInt16 BaseDataVariableType Mandatory ... Conformance Units BNM Ethernet Base Info Speed of DataType UInt64 specifies the configured, negotiated, or actual speed of an Ethernet port in entities of 1 Mb/s (data rate). The default
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network ModelHasComponent Variable OperStatus InterfaceOperStatus BaseDataVariableType M HasComponent Variable PhysAddress String BaseDataVariableType O HasComponent Variable Speed UInt64 AnalogUnitType M HasLowerLayerInterface Object <InterfaceName> BaseObjectType OP Conformance Units BNM IETF Interface ... Interfaces Group MIB). For the formal definition of AdminStatus, OperStatus, PhysAddress and Speed please refer to 5.2.1 . The HasLowerLayerInterface Reference points to an Object implementing the IIetfBaseNetworkInterfaceType used to indicate
-
OPC-40200 – OPC UA for Weighing Technology7.24.3 ObjectType Descriptiondefined control signal (volumetric mode) e.g., run a motor at a pre-defined speed without taking into account the TargetFlowRate . The value is usually read from the server. FlowRate defines ... allowed gravimetric flow rate (upper limit). MinFlowRate set minimum gravimetric flow rate (lower limit). Speed defines the speed of the volumetric feeding device. RateControlMode defines the mode in which
-
OPC-40200 – OPC UA for Weighing Technologyadded/changed in ContinuousScaleType BREAKING CHANGE 7.24 MaxFlowRate and MinFlowRate changed to optional added ControlMagnitude , Speed , RateControlMode, TargetFlowRate and Load removed HopperWeight Components added in LossInWeightScaleType BREAKING CHANGE 7.26 added mandatory