Search
4 result(s) for SafetyProviderLevel
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.3.3.3 SPI of SafetyProvidermacro <ParametersOK?> in Table 33 . See 9.1.1 for more information on GUID . SafetyProviderLevel Byte 0x01 to 0x04 n.a. R The SIL the SafetyProvider implementation (hardware and software ... independent from the generation of the SafetyData at SAPI . NOTE 2 The SafetyProviderLevel is used to distinguish devices of a different SIL . As a result, SPDUs coming from a device
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safetysafe substitute values due to an incorrect ID. Operator acknowledgment is required. Mismatch of SafetyProviderLevel .4 0x14 B, E Yes CRCerrIgn The SafetyConsumer has discarded a message ... shown when the error in the SPDU_ID is due to an incorrect SafetyProviderLevel . 5 A diagnostic message is generated only if the parameter SPI.SafetyOperatorAckNecessary is true, see transition
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetyPresentation of the SPDU_ID SPDU_ID_1:= SafetyBaseID (octets 0…3) XOR SafetyProviderLevel_ID (octets 0…3) SPDU_ID_2:= SafetyBaseID (octets 4…7) XOR SafetyStructureSignature (octets ... differs, but SPDU_ID_2 and SPDU_ID_3 do not, the SafetyProviderLevel does not match. By these rules, there is a very low probability (<10-9) that
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetyCoding of the SafetyProviderLevel_ID The SafetyProviderLevel is the SIL the SafetyProvider implementation (hardware and software) is capable of. Table 37 - Coding for the SafetyProviderLevel_ID SafetyProviderLevel Value of SafetyProviderLevel ... values provided in Table 37 shall be used as constant code value for SafetyProviderLevel_ID . The values were chosen in such a way that the hamming distance between them becomes