Search
3 result(s) for SafetyProviderIDConfigured
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetyFalse References Node class BrowseName DataType TypeDefinition Modelling rule Subtype of BaseObjectType HasProperty Variable SafetyProviderIDConfigured UInt32 PropertyType Mandatory HasProperty Variable SafetyProviderIDActive UInt32 PropertyType Mandatory HasProperty Variable SafetyBaseIDConfigured Guid PropertyType Mandatory ... SafetyBaseID exist in pairs for "Configured" and "Active" states: SafetyProviderIDConfigured and SafetyProviderIDActive , SafetyBaseIDConfigured and SafetyBaseIDActive . The "[...]Configured" parameters shall always deliver the values
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.3.3.2 SAPI of SafetyProvidercase, the SafetyProvider uses this value instead of the value from the SPI parameter SafetyProviderIDConfigured . If the value is changed to "0", the value of parameter SafetyProviderIDConfigured from
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.3.4.2 SAPI of SafetyConsumervalue. In this case, the SafetyConsumer uses this variable instead of the SPI parameter SafetyProviderIDConfigured . This input is only read in the first cycle, or when a rising edge occurs ... changed to "0", the value of SPI parameter SafetyProviderIDConfigured will be used (again). For static systems, this input is usually always kept at value "0". SafetyBaseID