OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementRunningToEnded 0:TransitionType None 0:HasComponent Object RunningToInterrupted 0:TransitionType None 0:HasComponent Object RunningToRunning 0:TransitionType None 0:IsDeprecated Object MachineTool_v102 0:BaseObjectType Conformance Units MachineTool Production LastTransition ... StateNumber 4 InitializingToRunning 0:TransitionNumber 0 RunningToEnded 0:TransitionNumber 1 EndedToInitializing 0:TransitionNumber 2 RunningToRunning 0:TransitionNumber 3 RunningToInterrupted 0:TransitionNumber 4 InterruptedToRunning 0:TransitionNumber 5 RunningToAborted 0:TransitionNumber
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementRunningToEnded 0:TransitionType None 0:HasComponent Object RunningToInterrupted 0:TransitionType None 0:HasComponent Object RunningToRunning 0:TransitionType None 0:IsDeprecated Object MachineTool_v102 0:BaseObjectType Conformance Units MachineTool Production ProductionJobStateMachineType ... different job. The values of this new job are sent with the ProductionJobTransitionEventType . RunningToRunning is triggered when a new run of the job starts. The RunsCompleted of the affected ProductionJobType