Search
11 result(s) for RIO Channel Group
-
OPC-30142 – OPC UA for PROFINET Remote IOfield. The bit field and the RIO Channel Objects are related using RIO Channel Group Objects . The Output Signal Objects "01_AO_1_Value ... Object connects to the RioFaAnalogChannelGroupType Object using a 0:RepresentsSameFunctionalityAs Reference . Since the RIO Channel Group types allow aggregating of Input and Output but are separated into different types
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.1 RioChannelGroupTypeVariable contains the number of channels of each supported type represented by the RIO Channel Group . The following table contains the relationship of array index and the channel number information ... this Variable by invoking the SetApplicationTag Method . If no subordinated RIO Channel Objects are provided, the Channel Group level ApplicationTag Variable is the only possibility to store Client specific semantic
-
OPC-30142 – OPC UA for PROFINET Remote IOthese properties. Each supported property applies to all represented channels of the RIO Channel Group . The Server may provide only one of the PaDigitalSubstituteValue , FaDigitalSubstituteValue bit fields, as well ... actual value of the SubstitutePolicy Property . If the number of RIOforFA Channels the RIO Channel Group represents exceeds the capacity of the RioBitFieldVariableType (which is 32), as many RioBitFieldVariableType Variables
-
OPC-30142 – OPC UA for PROFINET Remote IOInputImageValues array Variable contains the Input Process Values of the Input Channels the RIO Channel Group Object represents. The InputImageValues Variable is linked to the associated PnIoTelegramType Input Object using ... field representing the qualifier bits associated with each Input Process Value the RIO Channel Group Object represents. The InputImageQualifiers Variable is linked to the associated PnIoSignalType Input Object using
-
OPC-30142 – OPC UA for PROFINET Remote IOOutput Channels > minus 1. If the number of RIO Channels the RIO Channel Group represents exceeds the capacity of the RioBitFieldVariableType (which is 32), as many RioBitFieldVariableType Variables shall ... part of the RIO Channel Group Object as are needed to represent the qualifiers of all RIO Channels . The BrowseNames of the RioBitFieldVariableType Variables shall be extended with a suffix
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.1 RioChannelTypenumber. Uniqueness shall be guaranteed for all RIO Channel Objects aggregated by a RIO Channel Group . The value range used for the RioChannelNumber Property Values shall be continuous and start
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.1.1 SetApplicationTag Methoddata by sending RioChannelDiagnosisEventType Events and / or RioChannelDiagnosisAlarmType Events . The diagnosis data of the RioChannelGroup Object includes the diagnosis information of all aggregated RIO Channel Objects. If the SetApplicationTag Method
-
OPC-30142 – OPC UA for PROFINET Remote IO11.1 HasRioInputChannelHasComponent defined in OPC 10000-5 . The semantic of this ReferenceType is to connect RioChannelGroup Objects with Input Channel Objects . The HasRioInputChannel Reference is formally defined in Table 131 . Table
-
OPC-30142 – OPC UA for PROFINET Remote IO11.2 HasRioOutputChannelHasComponent defined in OPC 10000-5 . The semantic of this ReferenceType is to connect RioChannelGroup Objects with Output Channel Objects . The HasRioOutputChannel Reference is formally defined in Table 132 . Table
-
OPC-30142 – OPC UA for PROFINET Remote IOHasComponent defined in OPC 10000-5 . The semantic of this ReferenceType is to connect RioChannelGroup Objects with bit field and array Variables containing Process Values . The HasRioProcessVariable Reference is formally
-
OPC-30142 – OPC UA for PROFINET Remote IO11.4 HasRioConfigurationHasComponent defined in OPC 10000-5 . The semantic of this ReferenceType is to connect RioChannelGroup Objects with RioChannelGroupConfigType Objects . The HasRioConfiguration Reference is formally defined in Table 134 . Table