1 result(s) for READY:
-
OPC-40550-1 – OPC UA for Woodworking Machines - Part 1: Vertical InterfaceDescription OFFLINE 0 The unit is offline. STANDBY 1 The unit is in standby. READY 2 The unit is ready to start working. WORKING 3 The unit is working. ERROR ... state: OFFLINE: !MachineOn STANDBY: MachineOn && (!MachineInitialized || EnergySaving || (!Error && !Calibrated)) READY: MachineOn && MachineInitialized && !EnergySaving && !Error && Calibrated && !RecipeInRun