Search
8 result(s) for Qualifier
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety3.1.2.9 qualifierqualifier attribute (bit or Boolean), indicating whether the corresponding value is valid or not (e.g. being a fail-safe substitute value
-
OPC-30142 – OPC UA for PROFINET Remote IOProcess Value Qualifier and StatusCode Relationship for RIOforPA RIOforPA status information is conveyed to the Client as copy of the original status transmitted in the telegram signal. The value ... RioPaProcessValueQualifierVariableType Variable and the Qualifier member of the RioPaAnalogValueDataType and the RioPaDigitalValueDataType shall contain the original status. In addition to this, the status can be encoded into additional qualifier values
-
OPC-30142 – OPC UA for PROFINET Remote IOProcess Value Qualifier and StatusCode Relationship for RIOforFA RIOforFA status information is conveyed to the Client as copy of the original status transmitted in the telegram signal. The value ... RioFaProcessValueQualifierVariableType Variable and the Qualifier member of the RioFaAnalogValueDataType and the RioFaDigitalValueDataType shall contain the original status. In addition to this, the status can be encoded into additional qualifier values
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.5 SetSimulationValue Methodconstraints defined in chapter 6.7 apply. Signature SetSimulationValue ( [in] RioAnalogDataType Value [in] 0:Byte Qualifier ); Argument Description Value Desired content of the Value struct member of the SimulationValue Variable . Qualifier ... Desired content of the Qualifier struct member of the SimulationValue Variable . The Method Result Codes (defined in Call Service) are defined in Table 36 . Table 36 - Possible Method result codes
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.5 SetSimulationValue Methoddefined in chapter 6.7 apply. Signature SetSimulationValue ( [in] 0:RioAnalogDataType Value [in] 0:Byte Qualifier ); Argument Description Value Desired content of the Value member of the SimulationValue Variable . Qualifier Desired ... content of the Qualifier member of the SimulationValue Variable . The Method Result Codes (defined in Call Service) are defined in Table 42 . Table 42 - Possible Method result codes Result Code
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.5 SetSimulationValue Methoddefined in chapter 6.7 apply. Signature SetSimulationValue ( [in] 0:Boolean Value [in] 0:Byte Qualifier ); Argument Description Value Desired content of the Value member of the SimulationValue Variable . Qualifier Desired ... content of the Qualifier member of the SimulationValue Variable . The Method Result Codes (defined in Call Service) are defined in Table 48 . Table 48 - Possible Method result codes Result Code
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.5 SetSimulationValue Methoddefined in chapter 6.7 apply. Signature SetSimulationValue ( [in] 0:Boolean Value [in] 0:Byte Qualifier ); Argument Description Value Desired content of the Value member of the SimulationValue Variable . Qualifier Desired ... content of the Qualifier member of the SimulationValue Variable . The Method Result Codes (defined in Call Service) are defined in Table 54 . Table 54 - Possible Method result codes Result Code
-
OPC-30142 – OPC UA for PROFINET Remote IO7.3.2 PnIoTelegramTypebytes) of the IO Telegram . The ProviderStatus Variable contains the data provider's Qualifier for the IO Telegram (IOPS according to [ PN Service ]) encoded as PnIoTelegramStatusEnumeration . The ConsumerStatus Variable contains ... data consumer's Qualifier for the IO Telegram (IOCS according to [ PN Service ] is not relevant for RIOforFA, therefore ConsumerStatus is optional) encoded as PnIoTelegramStatusEnumeration