Search
6 result(s) for Method,
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.2 ConditionTypeMandatory HasComponent Variable Comment LocalizedText ConditionVariableType Mandatory HasProperty Variable ClientUserId String PropertyType Mandatory HasComponent Method Disable Defined in Clause 5.5.4 Mandatory HasComponent Method Enable Defined in Clause 5.5.5 Mandatory HasComponent ... Method AddComment Defined in Clause 5.5.6 Mandatory HasComponent Method ConditionRefresh Defined in Clause 5.5.7 HasComponent Method ConditionRefresh2 Defined in Clause 5.5.8 ConformanceUnits A & C Basic Table 9 - ConditionType Additional
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.2 AlarmConditionTypeOptionalPlaceholder HasProperty Variable ReAlarmTime Duration PropertyType Optional HasComponent Variable ReAlarmRepeatCount Int16 BaseDataVariableType Optional HasComponent Method Reset Defined in 5.8.5 Optional HasComponent Method Reset2 Defined in 5.8.6 5.8.5 Optional HasComponent Method ... Silence Defined in 5.8.7 Optional HasComponent Method Suppress Defined in 5.8.8 Optional HasComponent Method Suppress2 Defined in 5.8.9 Optional HasComponent Method Unsuppress Defined in 5.8.10 Optional HasComponent Method Unsuppress2 Defined
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model5.2.2.3 Asset compatibilitydetermined by vendor-specific tools or a vendor's Asset . The IAssetRevisionType VerifyAsset Method, combined with the AssetVerificationModeEnum AssetCompatibility, allows verifying an Asset's compatibility; see 6.3.3 for a detailed
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.4.2 PubSubDataSetWriters for each requested TransportProfileUri . For additional details, see OPC 10000-14 ReserveIds Method, including error definitions. If any error occurs, the EstablishConnections implementation shall abort processing as described
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model10.30 LastActivityMaskwith any of the other bits. If the ConnectionManager supports the ProcessConnectionConfigurationSets Method , then the activities correspond to the described actions in the Method , but a ConnectionManager is not required ... support the ProcessConnectionConfigurationSets Method , it could still have internal or application trigger activities that correspond to these actions. The LastActivityMask values are formally defined in Table 186 . Table 186 - LastActivityMask
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions18.4.7.9 StopAtCycleEndStopAtCycleEnd With this Method, the MES directs the machine to stop at the end of the current cycle. Signature StopAtCycleEnd (); The method has no Input - or OutputArguments . Table 91 - StopAtCycleEndMethod