Search
24 result(s) for HistoricalDataNodes
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access3.1.4 HistoricalNodeseries data or Events stored for this HistoricalNode . The term HistoricalNode refers to both HistoricalDataNodes and HistoricalEventNodes
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access3.1.5 HistoricalDataNodeinformation (open/closed, moving) dynamically changing system data (like stock quotes) diagnostic data The term HistoricalDataNodes is used when referencing aspects of the standard that apply to accessing historical data only
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access4.5 Timestampswith invalid settings will be rejected with Bad_TimestampsToReturnInvalid (see OPC 10000-4 ). For HistoricalDataNodes , the SourceTimestamp is used to determine which historical data values are to be returned ... SourceTimestamp and ServerTimestamp . NEITHER This is not a valid setting for any HistoryRead accessing HistoricalDataNodes. Any reference to timestamps in this context throughout this document will represent either ServerTimestamp
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessimpact a Client's ability to access historical information. If the history for a HistoricalDataNodes is still required, but the HistoricalDataNodes is no longer historized, then the Object should
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access5.1.1 GeneralGeneral The Historical Access model defines additional Properties that are applicable for both HistoricalDataNodes and HistoricalEventNodes
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessdefined interval. The ExceptionDeviation Variable specifies the minimum amount that the data for the HistoricalDataNodes shall change in order for the change to be reported to the history database
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical AccessHistoricalDataNodes Address Space Model HistoricalDataNodes are always a part of other Nodes in the AddressSpace. They are never defined by themselves. A simple example of a container for HistoricalDataNodes would
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Accessvalues. A value of True indicates the Server supports access to the history for HistoricalDataNodes , a value of False indicates the Server does not support access to the history ... HistoricalDataNodes . The default value is False. At least one of AccessHistoryDataCapability or AccessHistoryEventsCapability shall have a value of True for the Server to be a valid OPC UA Server supporting
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access5.7.3 Default configurationnodes, the Historian shall expose a default instance under the Server Object. If HistoricalDataNodes exist without a referenced configuration, an Object with a BrowseName of " DefaultHAConfiguration " shall
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.2.1 Overviewdefines additional codes and rules that apply to the StatusCode when used for HistoricalDataNodes . The general structure of the StatusCode is specified in OPC 10000-4 . It includes
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.2.4 Read modified functionalitymodification from the history database for the specified time domain for one or more HistoricalDataNodes . If there are multiple replaced Events the Server shall return all of them. The updateType
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.3.2 Read raw functionalitytimestamps from the history database for the specified time domain for one or more HistoricalDataNodes . This parameter is intended for use by a Client that wants the actual data saved
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.3.3 Read modified functionalitymodification from the history database for the specified time domain for one or more HistoricalDataNodes . If there are multiple replaced values the Server shall return all of them. The updateType
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.4.2 Read processed functionalitydata in the history database for the specified time domain for one or more HistoricalDataNodes . The time domain is divided into intervals of duration ProcessingInterval . The specified Aggregate Type
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.5.2 Read at time functionalityqualities from the history database for the specified timestamps for one or more HistoricalDataNodes . This function is intended to provide values to correlate with other values with a known timestamp
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical AccessAnnotation Data from the history database for the specified timestamps for one or more HistoricalDataNodes . It will return any annotation that is associated with the given HistoricalDataNodes . The ExtraData ... timestamps supplied in the request. If Annotation Data is not supported for a HistoricalDataNodes then the StatusCode shall be Bad_HistoryOperationUnsupported. The standard ContinuationPoint rules (see 6.3 ) apply
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.1 Overviewvalues into the history database at the specified timestamps for one or more HistoricalDataNodes The Variable 's value is represented by a composite value defined by the DataValue data type ... existing values into the history database at the specified timestamps for one or more HistoricalDataNodes . The Variable 's value is represented by a composite value defined by the DataValue data
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.2.2 Insert data functionalityinserts entries into the history database at the specified timestamps for one or more HistoricalDataNodes . If an entry exists at the specified timestamp, then the new entry shall
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.2.3 Replace data functionalityreplaces entries in the history database at the specified timestamps for one or more HistoricalDataNodes . If no entry exists at the specified timestamp, then the new entry shall
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.2.4 Update data functionalityreplaces entries in the history database for the specified timestamps for one or more HistoricalDataNodes . If the item has an entry at the specified timestamp, then the new entry will
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.5.2 Delete raw functionalityentries from the history database for the specified time domain for one or more HistoricalDataNodes . If no data is found in the time range for a particular HistoricalDataNode , then
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.5.3 Delete modified functionalityentries from the history database for the specified time domain for one or more HistoricalDataNodes . If no data is found in the time range for a particular HistoricalDataNode , then
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.6.2 Delete at time functionalityAnnotations in the history database for the specified timestamps for one or more HistoricalDataNodes . This parameter is intended to be used to delete specific data from the history database
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.2.1 Overviewwhich function to perform. The ReadProcessedDetails structure is used to read aggregated data for HistoricalDataNodes . The CreateMonitoredItems Service allows specifying a filter for each MonitoredItem . The MonitoringFilter is an extensible