OPC-30020 – MDIS OPC UA Companion SpecificationHasComponent Variable OperationMode CIMVOperationModeEnum 0:BaseDataVariableType M, RO 0:HasComponent Variable FlowRate 0:Float 0:AnalogItemType M, RO 0:HasComponent Variable TargetFlowRate 0:Float 0:AnalogItemType M, RO 0:HasComponent ... HasComponent Variable Count 0:UInt32 0:BaseDataVariableType M MotorOperationsCount 0:HasComponent Method SetCount M FlowRate 0:HasProperty Variable 0:EngineeringUnits 0:EUInformation 0:PropertyType M TargetFlowRate 0:HasProperty Variable
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.5 SetFlowRate MethodMethod is used to set a target flow rate. Signature SetFlowRate ( [in] 0:Float FlowRate, [in] SEMEnum SEM, [in] 0:Boolean ShutdownRequest); Table 62 - SetFlowRate Method Arguments Argument Description FlowRate ... overriding of any interlocks and the SEM selection to use for the command. The FlowRate Method argument is of datatype float however the actual units are device specific. Refer
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 Serverreference to a Variable of InterlockVariableType . CIMV Server MDIS CIMV Base Supports the OperationMode , FlowRate , TargetFlowRate, Position, TargetPosition and Moving variable, as well as the SetFlowRate , SetPosition and Stop methods
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devices10.19 PumpControlModeFLOW Flow rate controlled: the pump is controlled according to the specified nominal value FlowRate 4 TEMP_DIFF Temperature difference controlled: the pump is controlled according to the specified nominal
-
OPC-40200 – OPC UA for Weighing Technology7.24.3 ObjectType Descriptionwithout taking into account the TargetFlowRate . The value is usually read from the server. FlowRate defines current measured flow rate in mass per time. MasterTotalizer defines the overall material quantity
-
OPC-40200 – OPC UA for Weighing Technology7.25.3 ObjectType DescriptionMaterialDensity defines the bulk density of the used material. TargetFlowRate defines a preset of flowrate that needs to be conveyed. This value defines the setpoint for the FlowRate control loop
-
OPC-40718 – OPC UA for Surface Technology - Shot Blasting MachineryVariable FillLevel<n> 0:UInt16 0:AnalogUnitType OP Monitoring 0:HasComponent Variable FlowRate 0:Double 0:AnalogUnitType O Monitoring 0:HasComponent Variable ResidualDust 0:Double 0:AnalogUnitType ... this Variable is an optional placeholder it can be instantiated as often as needed. FlowRate is representing the air flow inside of the piping system. ResidualDust is representing the quality
-
OPC-40719 – OPC UA for Plasma Surface Technology7.8.1 OverviewHasComponent Object <CirculationSystem> CirculationSystemType OP 4:Monitoring 4:Process 0:HasComponent Variable FlowRate 0:Double 0:AnalogUnitType O, RO 4:Monitoring 4:Process 0:HasComponent Variable CoolingSystemTemperatureOutlet ... CirculationSystem is representing a single cooling circuit of the whole cooling system. FlowRate is representing the volume flow of coolant through the whole plant cooling system. CoolingSystemTemperatureOutlet is representing