Search
9 result(s) for EnergyDevicePowerOffType
-
OPC-30141 – OPC UA for PROFIenergy8.3.1 EnergyDevicePowerOffTypeEnergyDevicePowerOffType The EnergyDevicePowerOffType type provides access to the Sleep Mode WOL functionality of the device if supported. Table 32 - EnergyDevicePowerOffType Definition Attribute Value BrowseName EnergyDevicePowerOffType IsAbstract False References Node Class ... PESAP is not part of the Information Model , the RepresentedBy Reference in the EnergyDevicePowerOffType Object is omitted. The RegularTimeToOperate Variable shall contain the time value to reach the state
-
OPC-34100 – OPC UA for Energy Consumption Management7.3.1.1 OverviewOverview The EnergyDevicePowerOffType type provides access to the Sleep Mode WOL functionality of the device if supported. Table 38 - EnergyDevicePowerOffType Definition Attribute Value BrowseName EnergyDevicePowerOffType IsAbstract False References Node Class
-
OPC-30141 – OPC UA for PROFIenergy4.1.4 Sleep Mode WOLSleep Mode WOL state is initiated by invoking the SwitchOffWOL Method of the EnergyDevicePowerOffType . If the switched off device contains the OPC UA server, the connection of the OPC client
-
OPC-30141 – OPC UA for PROFIenergyEnergyStandbyManagementType Object , Clients can initiate the transition into an Energy Saving Mode . The EnergyDevicePowerOffType Object provides access to the devices' Sleep Mode WOL if supported. Clients can initiate the transition ... parts of the model offering Standby Management functions with related EnergyStandbyManagementType Object s. The EnergyDevicePowerOffType Object has no Reference to a functional part since the entire device is affected
-
OPC-30141 – OPC UA for PROFIenergyshows that all PE Energy Management Object instances ( EnergyStandbyManagementType Object , EnergyMeasurementType Object s and EnergyDevicePowerOffType Object ) are connected to a related PESAP Object using Represents References . Figure 10 - Example
-
OPC-30141 – OPC UA for PROFIenergyfunctionality. One optional Represents Reference with the BrowseName "EnergyPowerOff" points to an EnergyDevicePowerOffType Object if "Sleep Mode WOL" is supported
-
OPC-30141 – OPC UA for PROFIenergysemantic of this ReferenceType is to connect the EnergyMeasurementType, EnergyStandbyManagementType and EnergyDevicePowerOffType Object s of a PE Entity with the PeServiceAccessPointType Object . The SourceNode of References of this type shall ... PeServiceAccessPointType Object. The TargetNode shall be either EnergyMeasurementType Object, an EnergyStandbyManagementType Object or an EnergyDevicePowerOffType Object . The Represents Reference type is formally defined in Table 57 . Table 57 - Represents Definition
-
OPC-30141 – OPC UA for PROFIenergyPROFINET model offering Sleep Mode WOL functionality. Target shall be an Object of the EnergyDevicePowerOffType . The semantic of this ReferenceType is to connect the EnergyDevicePowerOffType Object s with the PROFINET
-
OPC-34100 – OPC UA for Energy Consumption Management6.4 Sleep Mode WOLSleep Mode WOL state is initiated by invoking the SwitchOffWOL Method of the EnergyDevicePowerOffType defined in 7.3.1 . If the switched off device contains the OPC UA server, the connection