OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.2.1 Descriptioneffect on the MonitoredItems referenced by the triggered items. Calling the CreateMonitoredItems Service repetitively to add a small number of MonitoredItems each time may adversely affect the performance ... Access Type Parts. Clients may receive Notifications for added MonitoredItems before the CreateMonitoredItems Response is received. Clients set the ClientHandle for the MonitoredItem in the CreateMonitoredItems Request and are therefore
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.2.4 StatusCodesspecific to this Service . Common StatusCodes are defined in Table 179 . Table 65 - CreateMonitoredItems Operation Level Result Codes Symbolic Id Description Bad_MonitoringModeInvalid See Table 179 for the description ... data exists within the range of indexes specified, Bad_IndexRangeNoData is returned in CreateMonitoredItems . Otherwise if the length of the array is dynamic, the Server shall return this status
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.3.1 DescriptionrevisedSamplingInterval . The return diagnostic info setting in the request header of the CreateMonitoredItems or the last ModifyMonitoredItems Service is applied to the Monitored Items and is used as the diagnostic
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.14.5.1 DescriptionSubscription and/or MonitoredItems . The return diagnostic info setting in the request header of the CreateMonitoredItems or the last ModifyMonitoredItems Service is applied to the Monitored Items and is used
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.22.4 AggregateFilterServer can return when an AggregateFilter is defined for a MonitoredItem in the CreateMonitoredItems or ModifyMonitoredItems Services . The AggregateFilterResult is defined in Table 147 . This is the MonitoringFilterResult associated with
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.2.1 Overviewperform. The ReadProcessedDetails structure is used to read aggregated data for HistoricalDataNodes . The CreateMonitoredItems Service allows specifying a filter for each MonitoredItem . The MonitoringFilter is an extensible parameter whose structure
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.1 GeneralGeneral When accessing aggregated data using the HistoryRead or the CreateMonitoredItems Service , the following rules are used to handle specific Aggregate use cases. If ProcessingInterva l is 0, the Server