OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.2 EstablishConnections signatureSignature EstablishConnections ( [in] 2:FxCommandMask CommandMask, [in] 2:AssetVerificationDataType[] AssetVerifications, [in] 2:ConnectionEndpointConfigurationDataType[] ConnectionEndpointConfigurations, [in] 2:ReserveCommunicationIdsDataType[] ReserveCommunicationIds, [in] 2:CommunicationConfigurationDataType[] CommunicationConfigurations, [out] 2:AssetVerificationResultDataType[] AssetVerificationResults, [out] 2:ConnectionEndpointConfigurationResultDataType[] ConnectionEndpointConfigurationResults ... element. If CommandMask VerifyAssetCmd is not set, AssetVerifications shall be null or empty. ConnectionEndpointConfigurations Provides configuration information for Connections . For a formal definition of the ConnectionEndpointConfigurationDataType, see 10.14 . If CommandMask
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.3 Command VerifyFunctionalEntityCmdEstablishConnections implementation shall execute the FunctionalEntityType Verify Method for each element in ConnectionEndpointConfigurations with a non-empty ExpectedVerificationVariables array. For elements with a null or empty ExpectedVerificationVariables array, the VerificationStatus
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.5 Command CreateConnectionEndpointCmdConnectionEndpoint or shall verify and update a preconfigured ConnectionEndpoint for each element in ConnectionEndpointConfigurations (see 10.14 ) with Parameter defined in ConnectionEndpoint (see 10.16 ). The EstablishConnections implementation shall set ConnectionEndpointConfigurationResults ConnectionEndpointResult
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.6 Command EstablishControlCmdshall call the EstablishControl Method on each element in ControlGroups for each element in ConnectionEndpointConfigurations . If ControlGroups is null or empty, EstablishControlResult shall be set to null or empty
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.7 Command SetConfigurationDataCmdEstablishConnections implementation shall apply the Value to the Key for each element in ConnectionEndpointConfigurations and each element in ConfigurationData . If the ConnectionEndpoint related to ConfigurationData has IsPersistent set, SetStoredVariables
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.8 Command ReassignControlCmdshall call the ReassignControl Method on each element in ControlGroups for each element in ConnectionEndpointConfigurations . If ControlGroups is null or empty, ReassignControlResult shall be set to null or empty
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.9.2 PubSubshall create the ToDataSetReader and ToDataSetWriter References according to the link information supplied in ConnectionEndpointConfigurations CommunicationLinks (see 10.13 ). If the PubSub configuration model is not exposed by this Server ... implementation shall verify the SubscribedDataSet associated with the referenced DataSetReader for each element in ConnectionEndpointConfigurations . If ExpectedSubscribedDataSetVersion MajorVersion is 0 (for the definition of MajorVersion
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.10.2 PubSuband/or DataSetWriterPath if the PubSub configuration model is not exposed) for each element in ConnectionEndpointConfigurations . It shall also ensure that the parent Objects ( WriterGroup , ReaderGroup , PubSubConnection , and PublishSubscribe ) are enabled
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modeladdress the referenced AutomationComponent . The ToConnectionEndpointConfiguration Reference is used to link an AutomationComponentConfiguration to ConnectionEndpointConfigurations (see 6.11 ). The ToOutboundFlow Reference is used to link a ConnectionEndpointConfiguration to a PubSubCommunicationFlowConfiguration
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelInputVariableIds or OutputVariableIds , the path shall be relative to the FunctionalEntityNode specified in the ConnectionEndpointConfigurations . A ConnectionEndpointParameter shall include at least one of the following fields: 1 or more InputVariableIds
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.13.1 Overviewchanges of a Client in the related elements in CommunicationModelConfiguration . CommunicationFlowConfigurations are referenced by ConnectionEndpointConfigurations using the ToOutboundFlow or ToInboundFlow References . The absence or presence of these References reflects ... types, see 5.5.1 . Examples of the configuration can be seen in Annex E . Multiple ConnectionEndpointConfigurations may reference the same CommunicationFlowConfiguration to share the set of configuration items (e.g., address
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelMulticast Publishing ConnectionEndpointConfiguration , if specified, references the PubSubCommunicationFlowConfiguration Object using the ToOutboundFlow Reference . Subscribing ConnectionEndpointConfigurations , if specified, shall reference the < SubscriberConfiguration > Objects using the ToInboundFlow Reference . There
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelconfiguration Connection1, which contains the configuration for a single logical connection. Connection1 contains two ConnectionEndpointConfigurations for the two ConnectionEndpoints EndpointA and EndpointB. Each ConnectionEndpointConfiguration contains all parameters required for creating
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelRelativePath is specified, the path shall be relative to the FunctionalEntityNode specified in the ConnectionEndpointConfigurations . True OutputVariableIds 4:NodeIdentifier[] OutVariableIds specifies a list of node identifiers to be used ... RelativePath is specified, the path shall be relative to the FunctionalEntityNode specified in the ConnectionEndpointConfigurations . True IsPersistent 0:Boolean IsPersistent , if TRUE, specifies the created ConnectionEndpoint shall be persistent. False