Search
8 result(s) for ConnectionConfigurationSetStateMachine
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnectionManager (see 6.7.6 ). AggregatedCurrentState shall be set to TRUE if one or more ConnectionConfigurationSets' ConnectionConfigurationSetStateMachine is in State Error . This only indicates that the ConnectionManager encountered a problem in processing
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.3.2 Establishing ConnectionsConnectionManager shall stop the establishing sequence and initiate a ProcessingToError transition in the ConnectionConfigurationSetStateMachine (see 6.9 ). If RollbackOnError is TRUE, the ConnectionManager shall call the Method CloseConnections for all ConnectionEndpoints
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.3.3 Closing Connectionscomplete closing all Connections in the ConnectionConfigurationSet and initiate a ProcessingToError transition in the ConnectionConfigurationSetStateMachine (see 6.9 ). If any of the ConnectionEndpoints require SKS configuration and were removed, the ConnectionManager
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelProcessConnectionConfigurationSets signature The ProcessConnectionConfigurationSets Method shall initiate the ReadyToProcessing or ErrorToProcessing transition in the ConnectionConfigurationSetStateMachine (see 6.9 ) on all requested ConnectionConfigurationSets . The Method triggers the processing and returns immediately
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelSubtype of the 0:BaseObjectType defined in OPC 10000-5 0:HasComponent Object 4:ConnectionConfigurationSetStateMachine 4:ConnectionConfigurationSetStateMachineType M 0:HasProperty Variable 4:Edit 0:Boolean 0:PropertyType ... Endpoint1 4:<AutomationComponentConfiguration> 4:ToConnectionEndpointConfiguration True 4:<Connection> 4:Endpoint2 ConnectionConfigurationSetStateMachine contains the current State of this ConnectionConfigurationSet . See 6.9 for a formal definition
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.9.1 Overviewprocessing failed) are only triggered internally on completion of Connection establishment processing. A ConnectionConfigurationSetStateMachine may transition to Error for several reasons. Transient errors will be resolved by re-processing
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnectionConfigurationSetProcessingStartedEventType This EventType is generated by a ConnectionConfigurationSetStateMachine upon transition from the Ready State to the Processing State as a result of a ConnectionManager starting to process the ConnectionConfigurationSet
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelequivalent to the ConnectionConfigurationSetType as defined in 6.8.2 with the exception that the elements ConnectionConfigurationSetStateMachine, Edit , and Lock as defined in the ConnectionConfigurationSetType are not part of this DataType ... this DataType is converted to an Object , the ConnectionConfigurationSetStateMachine shall be in State Ready, the Edit shall be set to False , and the Lock shall be assigned to the ConnectionManager