OPC-10000-100 – OPC Unified Architecture - Part 100: Devices8.3.4.9 Confirmation optionconfirmation option supports the use case of 8.2.2.9 : A Client can set a ConfirmationTimeout before the installation. After every reboot of the Server caused by the update , it shall wait
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices8.4.11.2 ConfirmationTimeoutConfirmationTimeout The ConfirmationTimeout can be set by a Client to a value other then 0 to enable the confirmation feature. If the value is not 0 and the Client - Server ... connection is lost, the ConfirmationTimeout represents the maximum time that the Client is required to reconnect and call the Confirm Method . The Server shall automatically reset the value
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices8.4.11.3 Confirm MethodConfirm Method After a reboot and with a ConfirmationTimeout other than 0 a Client shall call this Method to inform the Server that it has successfully reconnected. If this Method ... revert it. A Client is required to react within the time specified in the ConfirmationTimeout Variable . Signature Confirm