Search
8 result(s) for ByteStrings
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.7.3 FilterOperatorempty arrays of the same DataType as equal. This also applies to Strings and ByteStrings . Table 119 defines complex operators that require a target node (i.e. row) to evaluate. These
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.10 DataChangeTriggerempty arrays of the same DataType as equal. This also applies to Strings and ByteStrings . This is the default setting if no filter is set. STATUS_VALUE_TIMESTAMP 2 Report
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.27 NumericRangerange, the Server shall return partial results. For arrays of the ByteStrings and Strings find more details in the paragraphs below. Bad_IndexRangeInvalid is only used for invalid syntax
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.1.5 ByteStringcannot preserve the distinction it shall convert all one-dimensional arrays of Byte to ByteStrings . Each element in a one-dimensional array of ByteString can have a different length which ... DevelopmentPlatform does not support unsigned integers, then it will have to represent ByteStrings as arrays of SByte . In this case, the requirements for Byte would then apply to SByte
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappingszero-length are used to describe array values ( Strings are arrays of characters and ByteStrings are arrays of Bytes for purposes of this discussion). A null array has no value
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.2.2.16 Variantshall accept these IDs, assume the Value contains a ByteString or an array of ByteStrings and pass both onto the application. Encoders shall not use these IDs. The ArrayDimensions field ... Variants . Many implementation platforms do not distinguish between one dimensional Arrays of Bytes and ByteStrings . For this reason, decoders are allowed to automatically convert an Array of Bytes
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.5.11 RawData field encodingDataSet field or Structure field is an OptionSet , the length of the two ByteStrings in the OptionSet Structure is defined by highest bit number in the OptionSet definition. The following
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.4.4 InputsFolderTypehelp accomplish this. When using PubSub for periodic data with a fixed layout, Strings , ByteStrings, and variable-size arrays can cause problems. Without a defined maximum size for the Variables ... have fixed dimensions. NOTE The Server does define an overall maximum size for Arrays , ByteStrings and Strings , but typically, this global size is not appropriate for a specific Variable