Search
10 result(s) for ApplicationTag
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.1 RioChannelGroupTypeHasProperty Variable NumberOfChannels 0:UInt16[5] 0:PropertyType M, RO 0:HasProperty Variable ApplicationTag 0:String 0:PropertyType O, RO 0:HasComponent Method SetApplicationTag O 0:HasProperty Variable LastParameterChange ... input channels 3 Number of analog output channels 4 Number of universal channels. The ApplicationTag Variable contains application specific data which can be used by Clients to obtain additional semantic
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.1.1 SetApplicationTag MethodSetApplicationTag Method This Method sets the Value of the ApplicationTag Variable . The security constraints defined in chapter 6.7 apply. Signature SetApplicationTag ( [in] 0:String ApplicationTag ); Argument Description ApplicationTag String containing ... desired content of the ApplicationTag Variable. The Method Result Codes (defined in Call Service) are defined in Table 19 . Table 19 - Possible Method result codes Result Code Description Good
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.1 RioChannelTypeHasProperty Variable RioChannelNumber 0:UInt16 0:PropertyType M, RO 0:HasProperty Variable ApplicationTag 0:String 0:PropertyType M, RO 0:HasComponent Method SetApplicationTag O 0:HasProperty Variable LastParameterChange 0:DateTime ... used for the RioChannelNumber Property Values shall be continuous and start with 0. The ApplicationTag Variable contains information determined by configuration or by applications. The Client can change the content
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.1.1 SetApplicationTag MethodSetApplicationTag Method This Method sets the Value of the ApplicationTag Variable . The security constraints defined in chapter 6.7 apply. Signature SetApplicationTag ( [in] 0:String ApplicationTag ); Argument Description ApplicationTag String containing ... desired content of the ApplicationTag Variable . The Method Result Codes (defined in Call Service) are defined in Table 31 . Table 31 - Possible Method result codes Result Code Description Good
-
OPC-30142 – OPC UA for PROFINET Remote IOHasProperty Variable Reason RioChannelDiagnosisReasonEnumeration 0:PropertyType M, RO 0:HasProperty Variable ApplicationTag 0:String 0:PropertyType O, RO 0:HasProperty Variable ManufacturerData 0:ByteString 0:PropertyType O, RO 0:HasProperty ... status indicated with the Status Property encoded as RioChannelDiagnosisReasonEnumeration (see section 10.4.9 ) The ApplicationTag Property contains the Value of the ApplicationTag Property of the RioChannelType object which is the Alarm
-
OPC-30142 – OPC UA for PROFINET Remote IOHasProperty Variable Reason RioChannelDiagnosisReasonEnumeration 0:PropertyType M, RO 0:HasProperty Variable ApplicationTag 0:String 0:PropertyType O, RO 0:HasProperty Variable ManufacturerData 0:ByteString 0:PropertyType O, RO 0:HasProperty ... status indicated with the Status Property encoded as RioChannelDiagnosisReasonEnumeration (see section 10.4.9 ) The ApplicationTag Property contains the Value of the ApplicationTag Property of the RioChannelType object which is the Event
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>7.1.1 SetApplicationTag MethodSetApplicationTag Method This Method sets the Value of the ApplicationTag Variable . The security constraints defined in chapter 6.6 apply. Signature SetApplicationTag ( [in] 0:String ApplicationTag ); Argument Description ApplicationTag String containing ... desired content of the ApplicationTag Variable . The Method Result Codes (defined in Call Service) are defined in Table 15 . Table 15 - Possible Method Result Codes Result Code Description Good
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model7.1.1 SetApplicationTag MethodSetApplicationTag Method This Method sets the Value of the ApplicationTag Variable . The security constraints defined in chapter 6.11 apply. Signature SetApplicationTag ( [in] 0:String ApplicationTag ); Argument Description ApplicationTag String containing ... desired content of the ApplicationTag Variable . The Method Result Codes (defined in Call Service) are defined in Table 19 . Table 19 - Possible Method Result Codes Result Code Description Good
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives7.1 DriveAxisTypeOther Subtype of the 0:BaseObjectType defined in OPC 10000-5 . 0:HasProperty Variable ApplicationTag 0:String 0:PropertyType O, RO 0:HasComponent Method SetApplicationTag O 0:HasComponent Object Lock ... LogbookType O Conformance Units PDRV Measurement PDRV Diagnosis Events PDRV Signals General Properties The ApplicationTag Variable contains information given by the overall application. The purpose is to provide additional semantic
-
OPC-34100 – OPC UA for Energy Consumption ManagementNode Class BrowseName DataType TypeDefinition Other Subtype of the 0:BaseObjectType 0:HasProperty Variable ApplicationTag 0:String 0:PropertyType M, RW 0:HasComponent Variable <MeasurementValue> 0:BaseDataType ... PropertyType O 0:HasInterface ObjectType 2:IStatisticsType Conformance Units ECM Energy Measurement The ApplicationTag provides a string that is supposed to uniquely identify the functionality of the energy measurement