Search
15 result(s) for AnalogItemType
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.3.2.3 AnalogItemTypeAnalogItemType This VariableType requires the EURange Property . The AnalogItemType derives from the BaseAnalogType . It is formally defined in Table 3 . Table 3 - AnalogItemType definition Attribute Value BrowseName AnalogItemType IsAbstract False ... AnalogNumberItemType Defined in 5.3.2.6 HasProperty Variable EURange Range PropertyType Mandatory Conformance Units Data Access AnalogItemType
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.7.1 Method NodeClassvalue 42. Input2 as a numeric input argument with a HasArgumentDescription Reference to an AnalogItemType Variable which provides an engineering units range of 0 kPa to 100 kPa. Input3 ... instance of MyObjectType with an instance specific HasArgumentDescription Reference to an instance specific AnalogItemType Variable which provides an instance specific engineering range
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.3.2.5 AnalogUnitRangeTypeAnalogUnitRangeType The AnalogUnitRangeType derives from the AnalogItemType and additionally requires the EngineeringUnits Property . It is formally defined in Table 5 . Table 5 - AnalogUnitRangeType definition Attribute Value BrowseName AnalogUnitRangeType IsAbstract False ... DataType Number References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the AnalogItemType defined in 5.3.2.3 ; i.e. the Properties of that type are inherited. HasSubtype VariableType AnalogNumberUnitRangeType Defined in 5.3.2.7 HasProperty
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.3.2.6 AnalogNumberItemTypeAnalogNumberItemType This VariableType requires the EUNumberRange Property . The AnalogNumberItemType derives from the AnalogItemType . It is formally defined in Table 6 . Table 6 - AnalogNumberItemType definition Attribute Value BrowseName AnalogNumberItemType IsAbstract False ... DataType Number References NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of the AnalogItemType defined in 5.3.2.3 ; i.e. the Properties of that type are inherited. HasProperty Variable EUNumberRange NumberRange PropertyType Mandatory Conformance
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessTypeDefinition reference indicates the type of the DataItem (in this case the AnalogItemType ). Additional characteristics of DataItem s are defined using Properties . The VariableTypes in 5.2 specify which properties
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.3.1.3 ItemVariables . The VariableType depends on the existance of special DA properties as follows: AnalogItemType : An item in the DA server that has High EU and Low EU properties ... Type property is Analog is represented as Variable of AnalogItemType in the COM UA Wrapper. The AnalogItemType has the following Properties: EURange : The values of the High
-
OPC-30020 – MDIS OPC UA Companion SpecificationObjectTypes shall be used: Standard MDIS Objects defined in section 6 . BaseDataVariableType DiscreteItemType (Variable) AnalogItemType (Variable) Table 120 - Aggregation and Extension Decision Matrix Description Aggregation Extension Require new NodeId ... BaseDataType excluding structure. Yes Add an instance of an AnalogItemType to the newly created subtype of an MDIS ObjectType . Yes Add an instance of a DiscreteItemType to the newly created
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model5.2 Model OverviewUnits, Min_Pres_Value and Max_Pres_Value are mapped to an OPC UA AnalogItemType Variable with the name Present_Value Update is mapped to the OPC UA Attribute MinimumSamplingInterval
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.4.3.1 Variable Present_ValueValue Variable shall be writable when Out_Of_Service is true. This OPC UA AnalogItemType Variable represents the BACnet properties Present_Value, Min_Pres_Value, Max_Pres_Value, Units ... Update_Interval. The OPC UA VariableType AnalogItemType is defined in OPC 10000-8 . It defines the OPC UA Properties EURange , EngineeringUnits and InstrumentRange . The following list provides the BACnet property
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.18.3.1 Variable Present_ValueBACnet specification for information on the BACnet event enrolment model. This OPC UA AnalogItemType Variable represents the BACnet properties Present_Value, Minimum_Output, Maximum_Output, Output_Units and Update_Interval ... VariableType AnalogItemType is defined in OPC 10000-8 . It defines the OPC UA Properties EURange , EngineeringUnits and InstrumentRange . The following list provides the BACnet property and the mapping
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)6.4.6.2 CSPP elementintegral data type, or real data type, are mapped to the DataVariable of the AnalogItemType VariableType . All the CSPP elements other than the above are mapped to the DataVariable
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions6.2 AnalogItemTypeAnalogItemType For this specification, wherever AnalogItemType is used, the property EngineeringUnits is mandatory. The unit system described in OPC UA Part 8 ("Codes for Units of Measurement (Recommendation
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions22.1 ActualValueActualValue Actual value of the monitored parameter (unit given in AnalogItemType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions25.3 IntervalInterval Description: Regular interval between two maintenances. Use of AnalogItemType for flexible units (e.g. months, days, operating hours, m). Example
-
OPC-40200 – OPC UA for Weighing TechnologyScaleDeviceType ProductionOutput added in ScaleDeviceType - 7.4.2 ProductionOutput added in ScaleDeviceType - 7.4.2 Numerous changes from AnalogItemType to AnalogUnitType BREAKING CHANGE 7.1 MaximumFeederSpeed, MinimalFeederSpeed 7.2 LabelLength, LabelWidth 7.6 Tare, Throughput 7.8 PresetTare