Search
8 result(s) for Alarm Types
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.19.3 ExclusiveLimitAlarmTypeExclusiveLimitAlarmType The ExclusiveLimitAlarmType is used to specify the common behaviour for Alarm Types with multiple mutually exclusive limits. The ExclusiveLimitAlarmType is illustrated in Figure 20 . Figure 20 - ExclusiveLimitAlarmType The ExclusiveLimitAlarmType
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.20 NonExclusiveLimitAlarmTypeNonExclusiveLimitAlarmType The NonExclusiveLimitAlarmType is used to specify the common behaviour for Alarm Types with multiple non-exclusive limits. The NonExclusiveLimitAlarmType is illustrated in Figure 21 . Figure 21 - NonExclusiveLimitAlarmType The NonExclusiveLimitAlarmType
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Modelneeded for specific log information. If desired, subtypes of ConditionType or any of the AlarmTypes might also be used. The only requirement for an Event to be recorded
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.3.2 FxAssetType definitiondevice condition." " DeviceHealthAlarms shall be used for instances of the DeviceHealth AlarmTypes specified in OPC 10000-100 ." AlarmType instances can also be defined in other specifications, such
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices4.12.1 Generalhealth state of a device based on NAMUR NE 107. This section defines AlarmTypes that can be used to indicate an abnormal device condition together with diagnostic information text ... well as additional manufacturer specific information. Figure 15 informally describes the AlarmTypes for DeviceHealth. Figure 15 - Device Health Alarm type hierarchy
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basicsprovide the folder and the alarm Objects in the AddressSpace . Servers should use the AlarmTypes defined in OPC 10000-100 (2: DeviceHealthDiagnosticsAlarmType and subtypes) to expose the asset specific information
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics9.4.1 Overviewexpected, the interface IRootCauseIndicationType is defined (see 9.4.2 ). Servers providing this information shall use AlarmTypes implementing this interface for alarms indicating asset specific information on failures
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics9.4.2 IRootCauseIndicationTypeIRootCauseIndicationType The IRootCauseIndicationType is an interface and should be applied to AlarmTypes . It is formally defined in Table 16 . Note: The IRootCauseIndicationType cannot only be applied to AlarmTypes