The CirculationSystemType provides a representation of a single circuit of the cooling system of a plasma surface treatment machine. An Instance of the PlantCoolingSystemType can have several Instances of the CirculationSystemsType as components. The CirculationSystemType is formally defined in Table 46.

Table 46 – CirculationSystemType Definition

Attribute

Value

BrowseName

CirculationSystemType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of the BaseObjectType defined in OPC 10000-5

0:HasComponent

Variable

CoolingCircuitTemperatureOutlet

0:Double

0:AnalogUnitType

O, RO

0:HasComponent

Variable

CoolingCircuitFlowRate

0:Double

0:AnalogUnitType

O, RO

CoolingCircuitTemperatureOutlet is representing the temperature of the coolant at the outlet of the specific cooling circuit.

CoolingCircuitFlowRate is representing the volume flow of coolant through the specific cooling circuit.