The structure PhysicalAddressDataType defines parameters for the physical address of the manufacturer in Table 115.
Table 115 – PhysicalAddressDataType Structure
Name |
Type |
Description |
PhysicalAddressDataType |
structure |
Subtype of 0:Structure defined in OPC 10000-5. |
Street |
0:LocalizedText |
Street name where the manufacturer is located. |
Number |
0:LocalizedText |
Street number where the manufacturer is located. |
City |
0:LocalizedText |
City where the manufacturer is located. |
PostalCode |
0:LocalizedText |
Postal code where the manufacturer is located. |
State |
0:LocalizedText |
State where the manufacturer is located. |
Country |
0:LocalizedText |
Country where the manufacturer is located. |
The DeclarationOfConformityOptionSet defines flags for directives on the basis of which conformity was determined in Table 116.
Table 116 – DeclarationOfConformityOptionSet Values
Value |
Bit No. |
Description |
2006_42_EC |
0 |
Directives of the EU Declaration of Conformity - 2006/ 42/ EG, concerning machinery and amending Directive 95/16/EG |
2009_125_EC |
1 |
Directives of the EU Declaration of Conformity - 2009/ 125/ EC, establishing a framework for the setting of ecodesign requirements for energy-related products |
2011_65_EU |
2 |
Directives of the EU Declaration of Conformity - 2011/ 65/ EU, restriction of the use of certain hazardous substances in electrical and electronic equipment |
2014_35_EU |
3 |
Directives of the EU Declaration of Conformity - 2014/ 35/ EU, harmonization of the laws of the Member States on the provision of electrical equipment for use within certain voltage limits on the market |
2014_34_EU |
4 |
Directives of the SEU Declaration of Conformity - 2014/ 34/ EU, harmonization of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres |
2014_30_EU |
5 |
Directives of the EU Declaration of Conformity - 2014/ 30/ EU, harmonization of the laws of the Member States on electromagnetic compatibility |
2014_68_EU |
6 |
Directives of the EU Declaration of Conformity - 2014/ 68/ EU, harmonization of Member States' legislation on the provision of pressure equipment on the market |
2014_29_EU |
7 |
Directives of the EU Declaration of Conformity - 2014/ 29/ EU, harmonization of the laws of the Member States relating to the making available on the market of simple pressure vessels |
The DeclarationOfConformityOptionSet representation in the AddressSpace is formally defined in Table 117.
Table 117 – DeclarationOfConformityOptionSet Definition
Attribute |
Value |
||||
BrowseName |
DeclarationOfConformityOptionSet |
||||
IsAbstract |
False |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the OptionSet DataType defined in OPC 10000-5 |
|||||
0:HasProperty |
Variable |
OptionSetValues |
0:LocalizedText[] |
0:PropertyType |
M, RO |
The ExplosionProtectionOptionSet defines flags for the category of explosion protection for devices according to EU Directive 2014/34/EU (ATEX) in Table 118.
Table 118 – ExplosionProtectionOptionSet Values
Value |
Bit No. |
Description |
M1 |
0 |
This category is intended for use in underground mines and their surface installations which may be endangered by firedamp and/or combustible dust. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU) |
M2 |
1 |
This category is intended for use in underground mines and their surface installations which may be endangered by firedamp and/or combustible dust. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU) |
1G |
2 |
Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapors or mists is present. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU) |
2G |
3 |
Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapors or mists is present. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU) |
3G |
4 |
Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and gases, vapors or mists is present. Category 3 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a normal level of safety. (2014/34/EU) |
1D |
5 |
Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 1 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a very high level of safety. (2014/34/EU) |
2D |
6 |
Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 2 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a high level of safety. (2014/34/EU) |
3D |
7 |
Devices in this category are intended for use in areas in which an explosive atmosphere consisting of a mixture of air and dust is present. Category 3 comprises devices designed to be capable of functioning in conformity with the parameters specified by the manufacturer and ensuring a normal level of safety. (2014/34/EU) |
The ExplosionProtectionOptionSet representation in the AddressSpace is formally defined in Table 119.
Table 119 – ExplosionProtectionOptionSet Definition
Attribute |
Value |
||||
BrowseName |
ExplosionProtectionOptionSet |
||||
IsAbstract |
False |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the OptionSet DataType defined in OPC 10000-5 |
|||||
0:HasProperty |
Variable |
OptionSetValues |
0:LocalizedText[] |
0:PropertyType |
M, RO |
The ExplosionZoneOptionSet defines flags for the category of explosion zones for Pumps according to definitions from the hazardous substances ordinance (GefStoffV) in Table 120.
Table 120 – ExplosionZoneOptionSet Values
Value |
Bit No. |
Description |
Zone 0 |
0 |
A zone in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is present continuously or for long periods or frequently. |
Zone 1 |
1 |
A zone in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally. |
Zone 2 |
2 |
A zone in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. |
Zone 20 |
3 |
A zone in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, for long periods or frequently. |
Zone 21 |
4 |
A zone in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally. |
Zone 22 |
5 |
A zone in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only. |
The ExplosionZoneOptionSet representation in the AddressSpace is formally defined in Table 121.
Table 121 – ExplosionZoneOptionSet Definition
Attribute |
Value |
||||
BrowseName |
ExplosionZoneOptionSet |
||||
IsAbstract |
False |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the OptionSet DataType defined in OPC 10000-5 |
|||||
0:HasProperty |
Variable |
OptionSetValues |
0:LocalizedText[] |
0:PropertyType |
M, RO |
The OfferedControlModesOptionSet defines flags for offered control modes supported by the manufacturer of a Pump in Table 122. The Values and the associated Descriptions are based on the standard VDMA 24223.
Table 122 – OfferedControlModesOptionSet Values
Value |
Bit No. |
Description |
Constant pressure control |
0 |
Constant pressure control mode |
Constant temperature control |
1 |
Constant temperature control mode |
Differential pressure control |
2 |
Differential pressure control mode |
Constant differential pressure control |
3 |
Constant differential pressure control mode |
Variable differential pressure control |
4 |
Variable differential pressure control mode |
Flow_dependent differential pressure control |
5 |
Flow-dependent differential pressure control mode |
Return flow temperature control |
6 |
Return flow temperature control mode |
Flow temperature control |
7 |
Flow temperature control mode |
Flow rate control |
8 |
Flow rate control mode |
Automatic |
9 |
Automatic control mode |
Uncontrolled |
10 |
None / uncontrolled mode |
Speed control |
11 |
Speed control mode |
The OfferedControlModesOptionSet representation in the AddressSpace is formally defined in Table 123.
Table 123 – OfferedControlModesOptionSet Definition
Attribute |
Value |
||||
BrowseName |
OfferedControlModesOptionSet |
||||
IsAbstract |
False |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the OptionSet DataType defined in OPC 10000-5 |
|||||
0:HasProperty |
Variable |
OptionSetValues |
0:LocalizedText[] |
0:PropertyType |
M, RO |
The OfferedFieldbusesOptionSet defines flags for fieldbuses supported by the manufacturer of a Pump in Table 124.
Table 124 – OfferedFieldbusesOptionSet Values
Value |
Bit No. |
Description |
Other |
0 |
Additional fieldbuses listed in the AdditionalFieldbuses variable |
ARCNET |
1 |
ARCNET |
AS_Interface |
2 |
AS-Interface |
BACnet_IP |
3 |
BACnet/IP |
BACnet_MSTP |
4 |
BACnet/MSTP |
Bluetooth |
5 |
Bluetooth |
Bluetooth Low Energy |
6 |
Bluetooth Low Energy |
CAN |
7 |
CAN |
CANopen |
8 |
CANopen |
CC_Link |
9 |
CC-Link |
ControlNet |
10 |
ControlNet |
DALI |
11 |
DALI |
DECT ULE |
12 |
DECT ULE |
DeviceNet |
13 |
DeviceNet |
DMX |
14 |
DMX |
KNX |
15 |
KNX |
EnOcean |
16 |
EnOcean |
EtherCAT |
17 |
EtherCAT |
Ethernet_IP |
18 |
Ethernet/IP |
Ethernet TCP_IP |
19 |
Ethernet TCP/IP |
IEEE1588 |
20 |
IEEE1588 |
GSM |
21 |
GSM |
Interbus |
22 |
Interbus |
IO_Link |
23 |
IO-Link |
HART |
24 |
HART |
LON |
25 |
LON |
LoRaWAN |
26 |
LoRaWAN |
LIN_Bus |
27 |
LIN-Bus |
LTE |
28 |
LTE |
LTE_M |
29 |
LTE-M |
M_Bus |
30 |
M-Bus |
Modbus TCP |
31 |
Modbus TCP |
Modbus RTU |
32 |
Modbus RTU |
MP_Bus |
33 |
MP-Bus |
NB_IOT |
34 |
NB-IOT |
NFC |
35 |
NFC |
OPC UA |
36 |
OPC UA |
OPC DA |
37 |
OPC DA |
PROFIBUS DP |
38 |
PROFIBUS DP |
PROFINET RT |
39 |
PROFINET RT |
Powerlink |
40 |
Powerlink |
SERCOS |
41 |
SERCOS |
SMI |
42 |
SMI |
Thread |
43 |
Thread |
UMTS |
44 |
UMTS |
WIFI |
45 |
WIFI |
X2X_Link |
46 |
X2X-Link |
VARAN |
47 |
VARAN |
ZigBee |
48 |
ZigBee |
Z_Wave |
49 |
Z-Wave |
Other on Bit 0 is used to indicate that the manufacturer has added specific fieldbuses in the AdditionalFieldbuses Variable.
The OfferedFieldbusesOptionSet representation in the AddressSpace is formally defined in Table 125.
Table 125 – OfferedFieldbusesOptionSet Definition
Attribute |
Value |
||||
BrowseName |
OfferedFieldbusesOptionSet |
||||
IsAbstract |
False |
||||
References |
NodeClass |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the OptionSet DataType defined in OPC 10000-5 |
|||||
0:HasProperty |
Variable |
OptionSetValues |
0:LocalizedText[] |
0:PropertyType |
M, RO |
The enumeration ControlModeEnum defines possible Pump control modes in Table 126.
Table 126 – ControlModeEnum Items
Name |
Value |
Description |
ConstantPressureControl |
0 |
Constant pressure control mode |
ConstantTemperatureControl |
1 |
Constant temperature control mode |
DifferentialPressureControl |
2 |
Differential pressure control mode |
ConstantDifferentialPressureControl |
3 |
Constant differential pressure control mode |
VariableDifferentialPressureControl |
4 |
Variable differential pressure control mode |
FlowDependentDifferentialPressureControl |
5 |
Flow-dependent differential pressure control mode |
ReturnFlowTemperatureControl |
6 |
Return flow temperature control mode |
FlowTemperatureControl |
7 |
Flow temperature control mode |
FlowRateControl |
8 |
Flow rate control mode |
SpeedControl |
9 |
Speed control mode |
Automatic |
10 |
Automatic control mode |
Uncontrolled |
11 |
None / uncontrolled mode |
The ControlModeEnum representation in the AddressSpace is formally defined in Table 127.
Table 127 – ControlModeEnum Definition
Attribute |
Value |
||||
BrowseName |
ControlModeEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration PumpClassEnum defines possible Pump PumpClasss in Table 128.
Table 128 – PumpClassEnum Items
Name |
Value |
Description |
RotodynamicPump |
0 |
Rotodynamic pump |
PositiveDisplacementPump |
1 |
Positive displacement pump |
ProcessVacuumPump |
2 |
Process vacuum pump |
TurboVacuumPump |
3 |
Turbo vacuum pump |
VacuumPump |
4 |
Vacuum pump |
LiquidPump |
5 |
Liquid pump |
Pump |
6 |
Pump |
The PumpClassEnum representation in the AddressSpace is formally defined in Table 129.
Table 129 – PumpClassEnum Definition
Attribute |
Value |
||||
BrowseName |
PumpClassEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration DistributionTypeEnum defines possible Pump distributions in Table 130. The Values and the associated Descriptions are based on the standard VDMA 24223.
Table 130 – DistributionTypeEnum Items
Name |
Value |
Description |
ManufacturerSpecific |
0 |
Manufacturer specific distribution of operation time |
OperatorSpecific |
1 |
Operator specific distribution of operation time |
ConcerningTimeDistribution |
2 |
Equivalent distribution of operation time, concerning time distribution |
ConcerningLoadDistribution |
3 |
Equivalent distribution of operation time, concerning load distribution |
The DistributionTypeEnum representation in the AddressSpace is formally defined in Table 131.
Table 131 – DistributionTypeEnum Definition
Attribute |
Value |
||||
BrowseName |
DistributionTypeEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration ExchangeModeEnum defines possible Pump exchange modes in Table 132. The Values and the associated Descriptions are based on the standard VDMA 24223.
Table 132 – ExchangeModeEnum Items
Name |
Value |
Description |
ManufacturerSpecific |
0 |
Manufacturer specific pump exchange mode |
ExchangeDisabled |
1 |
Pump exchange disabled |
OperatorSpecific |
2 |
Operator specific pump exchange mode |
The ExchangeModeEnum representation in the AddressSpace is formally defined in Table 133.
Table 133 – ExchangeModeEnum Definition
Attribute |
Value |
||||
BrowseName |
ExchangeModeEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the 0:Enumeration type defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration FieldbusEnum defines possible Pump fieldbuses in Table 134.
Table 134 – FieldbusEnum Items
Name |
Value |
Description |
Other |
0 |
Fieldbus is not specified in this enumeration |
ARCNET |
1 |
ARCNET |
AS-Interface |
2 |
AS-Interface |
BACnet/IP |
3 |
BACnet/IP |
BACnet/MSTP |
4 |
BACnet/MSTP |
Bluetooth |
5 |
Bluetooth |
BluetoothLowEnergy |
6 |
Bluetooth Low Energy |
CAN |
7 |
CAN |
CANopen |
8 |
CANopen |
CC-Link |
9 |
CC-Link |
ControlNet |
10 |
ControlNet |
DALI |
11 |
DALI |
DECTULE |
12 |
DECT ULE |
DeviceNet |
13 |
DeviceNet |
DMX |
14 |
DMX |
KNX |
15 |
KNX |
EnOcean |
16 |
EnOcean |
EtherCAT |
17 |
EtherCAT |
Ethernet/IP |
18 |
Ethernet/IP |
EthernetTCP/IP |
19 |
Ethernet TCP/IP |
IEEE1588 |
20 |
IEEE1588 |
GSM |
21 |
GSM |
Interbus |
22 |
Interbus |
IO-Link |
23 |
IO-Link |
HART |
24 |
HART |
LON |
25 |
LON |
LoRaWAN |
26 |
LoRaWAN |
LIN-Bus |
27 |
LIN-Bus |
LTE |
28 |
LTE |
LTE-M |
29 |
LTE-M |
M-Bus |
30 |
M-Bus |
ModbusTCP |
31 |
Modbus TCP |
ModbusRTU |
32 |
Modbus RTU |
MP-Bus |
33 |
MP-Bus |
NB-IOT |
34 |
NB-IOT |
NFC |
35 |
NFC |
OPCUA |
36 |
OPC UA |
OPCDA |
37 |
OPC DA |
PROFIBUSDP |
38 |
PROFIBUS DP |
PROFINETRT |
39 |
PROFINET RT |
Powerlink |
40 |
Powerlink |
SERCOS |
41 |
SERCOS |
SMI |
42 |
SMI |
Thread |
43 |
Thread |
UMTS |
44 |
UMTS |
WIFI |
45 |
WIFI |
X2X-Link |
46 |
X2X-Link |
VARAN |
47 |
VARAN |
ZigBee |
48 |
ZigBee |
Z-Wave |
49 |
Z-Wave |
Manufacturer specific on Value 0 is used to indicate that a manufacturer specific fieldbus is needed.
The FieldbusEnum representation in the AddressSpace is formally defined in Table 135.
Table 135 – FieldbusEnum Definition
Attribute |
Value |
||||
BrowseName |
FieldbusEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration MaintenanceLevelEnum defines possible Pump maintenance levels in Table 136. The Values and the associated Descriptions are based on the standard DIN EN 13306.
Table 136 – MaintenanceLevelEnum Items
Name |
Value |
Description |
Level1 |
0 |
Level 1 is characterized by simple actions carried out with minimal training |
Level2 |
1 |
Level 2 is characterized by basic actions which have to be carried out by qualified personnel using detailed procedures |
Level3 |
2 |
Level 3 is characterized by complex actions carried out by qualified technical personnel using detailed procedures |
Level4 |
3 |
Level 4 is characterized by actions which imply the know-how of a technique or a technology and carried out by specialized technical personnel |
Level5 |
4 |
Level 5 is characterized by actions which imply a knowledge held by the manufacturer or a specialized company with industrial logistic support equipment |
The MaintenanceLevelEnum representation in the AddressSpace is formally defined in Table 137.
Table 137 – MaintenanceLevelEnum Definition
Attribute |
Value |
||||
BrowseName |
MaintenanceLevelEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration MultiPumpOperationModeEnum defines possible multi Pump operation modes in Table 138. The Values and the associated Descriptions are based on the standard VDMA 24223.
Table 138 – MultiPumpOperationModeEnum Items
Name |
Value |
Description |
Standalone |
0 |
Standalone mode |
RedundancyOperation |
1 |
pump fulfils the process function of another pump |
AdditionOperation |
2 |
supplementary fulfilling of the process function |
MixedRedundancy |
3 |
Redundancy and addition operation mixed |
The MultiPumpOperationModeEnum representation in the AddressSpace is formally defined in Table 139.
Table 139 – MultiPumpOperationModeEnum Definition
Attribute |
Value |
||||
BrowseName |
MultiPumpOperationModeEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration OperatingModeEnum Pump operating modes in Table 140.
Table 140 – OperatingModeEnum Items
Name |
Value |
Description |
SingleOperation |
0 |
Single operating mode |
SeriesOperation |
1 |
Series operating mode |
ParallelOperation |
2 |
Parallel operating mode |
The OperatingModeEnum representation in the AddressSpace is formally defined in Table 141.
Table 141 – OperatingModeEnum Definition
Attribute |
Value |
||||
BrowseName |
OperatingModeEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration OperationModeEnum defines possible Pump operation modes in Table 142. The Values and the associated Descriptions are based on the standard VDMA 24223.
Table 142 – OperationModeEnum Items
Name |
Value |
Description |
AutoControl |
0 |
standard control algorithm, not configurable |
ClosedLoopStandardPID |
1 |
pid algorithm, control parameters configurable in functional element ControlPID |
Advanced |
2 |
manufacturer specific control algorithm, control parameters configurable |
StandBy |
3 |
ready for operation |
OpenLoopMin |
4 |
open loop operation at minimum characteristic |
OpenLoopValue |
5 |
open loop operation at set point value |
OpenLoopMax |
6 |
open loop operation at maximum characteristic |
ClosedLoopMin |
7 |
closed loop operation at minimum characteristic |
ClosedLoopMax |
8 |
closed loop operation at maximum characteristic |
Test |
9 |
Test operation |
Calibration |
10 |
Calibration mode |
The OperationModeEnum representation in the AddressSpace is formally defined in Table 143.
Table 143 – OperationModeEnum Definition
Attribute |
Value |
||||
BrowseName |
OperationModeEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration PortDirectionEnum defines possible Port directions in Table 144. The Values and the associated Descriptions are based on the AutomationML semantic.
Table 144 – PortDirectionEnum Items
Name |
Value |
Description |
In |
0 |
Ports with the direction “In” can only be connected to ports with the direction “Out” or “InOut”. |
Out |
1 |
Ports with the direction “Out” can only be connected to ports with the direction “In” or “InOut”. |
InOut |
2 |
Ports with the direction “InOut” can be connected to ports with arbitrary directions. |
The PortDirectionEnum representation in the AddressSpace is formally defined in Table 145.
Table 145 – PortDirectionEnum Definition
Attribute |
Value |
||||
BrowseName |
PortDirectionEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration PumpKickModeEnum defines possible Pump kick modes in Table 146. The Values and the associated Descriptions are based on the standard VDMA 24223.
Table 146 – PumpKickModeEnum Items
Name |
Value |
Description |
ManufacturerSpecific |
0 |
Manufacturer specific pump kick mode |
Disabled |
1 |
Pump kick mode disabled |
OperatorSpecific |
2 |
Operator specific pump kick mode |
The PumpKickModeEnum representation in the AddressSpace is formally defined in Table 147.
Table 147 – PumpKickModeEnum Definition
Attribute |
Value |
||||
BrowseName |
PumpKickModeEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration PumpRoleEnum defines possible Pump roles in Table 148. The Values and the associated Descriptions are based on the standard VDMA 24223.
Table 148 – PumpRoleEnum Items
Name |
Value |
Description |
Slave |
0 |
Slave |
Master |
1 |
Master |
SlaveAndAuxiliaryMaster |
2 |
Slave and auxiliary master |
The PumpRoleEnum representation in the AddressSpace is formally defined in Table 149.
Table 149 – PumpRoleEnum Definition
Attribute |
Value |
||||
BrowseName |
PumpRoleEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|
The enumeration StateOfTheItemEnum defines possible Pump states in Table 150. The Values and the associated Descriptions are based on the standard DIN EN 13306.
Table 150 – StateOfTheItemEnum Items
Name |
Value |
Description |
IdleState |
0 |
Item is in up state and non-operating outside required time |
StandByState |
1 |
Item is in up state and non-operating during required time |
OperatingState |
2 |
Item is in up state and operating as required |
ExternalDisabledState |
3 |
Item is in up state, but lacks required external resources or is disabled due to planned actions other than maintenance |
DownState |
4 |
Item is unable to perform a required function due to preventive maintenance or a fault |
The StateOfTheItemEnum representation in the AddressSpace is formally defined in Table 151.
Table 151 – StateOfTheItemEnum Definition
Attribute |
Value |
||||
BrowseName |
StateOfTheItemEnum |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of 0:Enumeration defined in OPC 10000-5. |
|||||
0:HasProperty |
Variable |
0:EnumValues |
0:EnumValueType[] |
0:PropertyType |
|