The PtElectronicOverloadRelayAttributesType provides the common asset attributes of a contactor and is formally defined in Table 113. Additional attributes can be found in IEC Common Data Dictionary (CDD) 62683DB.
Table 113 – PtElectronicOverloadRelayAttributesType Definition
Attribute |
Value |
||||
BrowseName |
PtElectronicOverloadRelayAttributesType |
||||
IsAbstract |
False |
||||
References |
Node Class |
BrowseName |
DataType |
TypeDefinition |
Other |
Subtype of the PtAssetAttributesType defined in chapter 7.7 |
|||||
0:HasProperty |
Variable |
OverloadCurrentSettingRange |
0:Range |
0:PropertyType |
M, RO |
0:HasComponent |
Variable |
TripClass |
0:UInt16 |
0:MultiStateValueDiscreteType |
M, RO |
0:HasProperty |
Variable |
VoltageRated |
0:UInt16 |
0:PropertyType |
M, RO |
0:HasProperty |
Variable |
NumberofAuxiliaryContactsNC |
0:UInt16 |
0:PropertyType |
M, RO |
0:HasProperty |
Variable |
PhaseLossSensitiveSupported |
0:Boolean |
0:PropertyType |
M, RO |
0:HasProperty |
Variable |
JamDetectionSupported |
0:Boolean |
0:PropertyType |
M, RO |
0:HasProperty |
Variable |
StallDetectionSuported |
0:Boolean |
0:PropertyType |
M, RO |
0:HasProperty |
Variable |
GroundEarthFaultDetectionSupported |
0:Boolean |
0:PropertyType |
M, RO |
Conformance Units |
|||||
Powertrain Attributes Information |
TripClass provides the classification for thermal protective devices regarding the value of the maximum tripping time in seconds. The values of the MultiStateValueDiscreteType variable are defined in Table 114 and shall be used. The values 0-199 are reserved for future extensions of this specification. The values 200-299 shall be used for vendor-specific extensions of this variable.
Table 114 – PtElectronicOverloadRelayAttributesType values for child nodes
BrowsePath |
Value Attribute |
Description Attribute |
||
|
[ { "Value": 0, "DisplayName": "CLASS_2E", "Description": "Thermal protection class 2E" }, { "Value": 1, "DisplayName": "CLASS_3E", "Description": "Thermal protection class 3E" }, { "Value": 2, "DisplayName": "CLASS_5", "Description": "Thermal protection class 5" }, { "Value": 3, "DisplayName": "CLASS_5E", "Description": "Thermal protection class 5E" }, { "Value": 4, "DisplayName": "CLASS_10", "Description": "Thermal protection class 10" }, { "Value": 5, "DisplayName": "CLASS_10A", "Description": "Thermal protection class 10A" }, { "Value": 6, "DisplayName": "CLASS_10E", "Description": "Thermal protection class 10E" }, { "Value": 7, "DisplayName": "CLASS_20", "Description": "Thermal protection class 20" }, { "Value": 8, "DisplayName": "CLASS_20E", "Description": "Thermal protection class 20E" }, { "Value": 9, "DisplayName": "CLASS_30", "Description": "Thermal protection class 30" }, { "Value": 10, "DisplayName": "CLASS_30E", "Description": "Thermal protection class 30E" }, { "Value": 11, "DisplayName": "CLASS_40E", "Description": "Thermal protection class 40E" } ] |
|
The 0:EnumValues of the TripClass have additional CDD entries which are defined in Table 125.
Table 115 – TripClass CDD entries
0:EnumValues |
CDD entries |
CLASS_2E |
|
CLASS_3E |
|
CLASS_5 |
|
CLASS_5E |
|
CLASS_10 |
|
CLASS_10A |
|
CLASS_10E |
|
CLASS_20 |
|
CLASS_20E |
|
CLASS_30 |
|
CLASS_30E |
|
CLASS_40E |
All other PtElectronicOverloadRelayAttributesType properties are described in IEC Common Data Dictionary (CDD).
The properties of the PtElectronicOverloadRelayAttributesType have additional references which are defined in Table 116.
Table 116 – PtElectronicOverloadRelayAttributesType Additional References
SourceBrowsePath |
Reference Type |
Is Forward |
TargetBrowsePath |
|
|
|
|
OverloadCurrentSettingRange |
0:HasDictionaryEntry |
0:True |
|
TripClass |
0:HasDictionaryEntry |
0:True |
|
VoltageRated |
0:HasDictionaryEntry |
0:True |
|
NumberofAuxiliaryContactsNC |
0:HasDictionaryEntry |
0:True |
|
PhaseLossSensitiveSupported |
0:HasDictionaryEntry |
0:True |
|
JamDetectionSupported |
0:HasDictionaryEntry |
0:True |
|
StallDetectionSuported |
0:HasDictionaryEntry |
0:True |
|
GroundEarthFaultDetectionSupported |
0:HasDictionaryEntry |
0:True |