This chapter defines the corresponding profiles and conformance units for the OPC UA Information Model for OPC 40082-2. Profiles are named groupings of conformance units. Facets are profiles that will be combined with other Profiles to define the complete functionality of an OPC UA Server or Client. The following tables specify the facets available for Servers that implement the OPC 40082-2 Information Model companion specification.

NOTE: The names of the supported profiles are available in the Server Object under ServerCapabilities.ServerProfileArray

Table 23 lists all Profiles defined in this document and defines their URIs.

Table 23 – Profile URIs for OPC 40082-2

Profile

URI

OPC 40082-2 Basic Server Profile

http://opcfoundation.org/UA-Profile/PlasticsRubber/HotRunner/Server/Basic

OPC 40082-2 Alarms Server Facet

http://opcfoundation.org/UA-Profile/PlasticsRubber/HotRunner/Server/Alarms

OPC 40082-2 Diagnostics Server Facet

http://opcfoundation.org/UA-Profile/PlasticsRubber/HotRunner/Server/Diagnostics

OPC 40082-2 Maintenance Server Facet

http://opcfoundation.org/UA-Profile/PlasticsRubber/HotRunner/Server/Maintenance

Table 24 – OPC 40082-2 Basic Server Profile Definition

Conformance Unit

Description

Optional/

Mandatory

OPC 40082-2 Basic Server Profile

Support of HRD_lnterfaceType and all mandatory child elements giving information on the hot runner device itself, the current configuration and status.

M

Profile

ComplexType Server Facet (defined in OPC UA Part 7)

M

Method Server Facet (defined in OPC UA Part 7)

M

BaseDevice_Server_Facet (defined in OPC UA Part 100)

M

The OPC 40082-2 Basic Server Profile is mandatory for all HRD compliant with this specification. The following Facets are optional.

Table 25 – OPC 40082-2 Alarms Server Facet Definition

Conformance Unit

Description

Optional/

Mandatory

OPC 40082-2 Alarms Server Facet

Support of HelpOffNormalAlarmType and ZoneAlarmType providing error information. If this facet is supported and a client subscribes to the events, the server shall provide all errors via alarms in addition to the error variables included in the OperationType

M

A & C Alarm Server Facet (defined in OPC UA Part 7)

M

Table 26 – OPC 40082-2 Diagnostics Server Facet Definition

Conformance Unit

Description

Optional/

Mandatory

OPC 40082-2 Diagnostics Server Facet

Support of OPC 40082-2 diagnosis functions. Therefore, the component Diagnostics of HRD_InterfaceType is mandatory.

M

Table 27 – OPC 40082-2 Maintenance Server Facet Definition

Conformance Unit

Description

Optional/

Mandatory

OPC 40082-2 Maintenance Server Facet

Support of OPC 40082-2 maintance information. Therefore, the component MaintenanceInformation of HRD_InterfaceType is mandatory.

M