The ActiveErrorDataType is used for providing information about an active error in a device. It is used for minimal error handling for devices without alarm support.
Table 139 – ActiveErrorDataType Definition
Name |
Type |
Description |
ActiveErrorDataType |
structure |
Subtype of 0:Structure as defined in OPC UA 10000-3 |
Id |
0:String |
Unique identifier defined by manufacturer |
Severity |
0:UInt16 |
Severity as defined in the BaseEventType (1 = low – 1000 = high) |
Message |
0:LocalizedText |
Message giving information about the error |
The ClassifiedActiveErrorDataType is a subtype of the ActiveErrorDataType and adds the elements defined in Table 140 for additional information about errors.
Table 140 – ClassifiedActiveErrorDataType Definition
Name |
Type |
Description |
ClassifiedActiveErrorDataType |
structure |
Subtype of ActiveErrorDataType |
SourceNodes |
0:NodeId[] |
NodeIds of the Nodes which cause the error. This can be a component of the machine (e.g. temperature zone) or a process parameter expressed as MonitoredParameterType (e.g. temperature) |
Classification |
0:UInt16 |
Classification of the error, if a process parameter expressed as MonitoredParameterType is the cause of the error. As values (1 – 8), the same as defined in Table 127 are used.
If the error is not caused by a specific process parameter (e.g. failure of an component), Classification = 0. |