26.2 ClassifiedActiveErrorDataType

The ClassifiedActiveErrorDataType is a subtype of the ActiveErrorDataType and adds the elements defined in Table 140 for additional information about errors.

Table 140 – ClassifiedActiveErrorDataType Definition

Name

Type

Description

ClassifiedActiveErrorDataType

structure

Subtype of ActiveErrorDataType

SourceNodes

0:NodeId[]

NodeIds of the Nodes which cause the error. This can be a component of the machine (e.g. temperature zone) or a process parameter expressed as MonitoredParameterType (e.g. temperature)

Classification

0:UInt16

Classification of the error, if a process parameter expressed as MonitoredParameterType is the cause of the error. As values (1 – 8), the same as defined in Table 127 are used.

If the error is not caused by a specific process parameter (e.g. failure of an component), Classification = 0.