8 TemperatureZones
8.1 ExtrusionTemperatureZonesType
This ObjectType is a container for temperature zones inside of a component of an extrusion line. It is formally defined in Table 10.
| Attribute | Value | ||||
| BrowseName | ExtrusionTemperatureZonesType | ||||
| IsAbstract | False | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Other |
|---|---|---|---|---|---|
| Subtype of 0:BaseObjectType defined in OPC 10000-5 | |||||
| 0:HasProperty | Variable | 0:NodeVersion | 0:String | 0:PropertyType | M, RO |
| 0:HasComponent | Object | StartTempering | 3:StartDeviceType | O | |
| 0:HasComponent | Object | Maintenance | 3:MaintenanceType | O | |
| 0:HasComponent | Object | TemperatureZone_<Nr> | ExtrusionTemperature ZoneType | OP | |
| 0:GeneratesEvent | ObjectType | 0:GeneralModelChange EventType | |||
When instances for temperature zones are created, the BrowseNames shall be “TemperatureZone_<Nr>” where <Nr> is a three-digit number with leading zeros, starting with “001”. The ExtrusionTemperatureZoneType is defined in Table 11.
StartTempering: Main switch for all temperature zones in the container. The single zones have own switches/status AND-connection!
8.2 ExtrusionTemperatureZoneType
This ObjectType represents one temperature zone inside of a component of an extrusion line. It is formally defined in Table 11.
| Attribute | Value | ||||
| BrowseName | ExtrusionTemperatureZoneType | ||||
| IsAbstract | False | ||||
| References | Node Class | BrowseName | DataType | TypeDefinition | Other |
|---|---|---|---|---|---|
| Subtype of 3:MeasuringDeviceType defined in OPC 40083 | |||||
| 0:HasComponent | Variable | NominalHeatingPower | 0:Double | 0:AnalogUnitType | O, RO |
| 0:HasComponent | Variable | NominalCoolingPower | 0:Double | 0:AnalogUnitType | O, RO |
| 0:HasComponent | Variable | ControllerOutput | 0:Double | 0:AnalogUnitType | O, RO |
| 0:HasComponent | Object | ElectricalCurrent | 3:MonitoredParameterType | O | |
8.2.1 NominalHeatingPower
Indication of the nominal heating power of the zone in kW. If the zone is only a cooling zone, this variable is not used.
8.2.2 NominalCoolingPower
Indication of the nominal cooling power of the zone in kW. If the zone is only a heating zone, this variable is not used.
8.2.3 ControllerOutput
Actual ratio of the used nominal power in %. Values from -100 (=max. cooling) to +100 (max. heating).
8.2.4 ElectricalCurrent
Actual electrical current of the zone in A.