8 TemperatureZones

8.1 ExtrusionTemperatureZonesType

This ObjectType is a container for temperature zones inside of a component of an extrusion line. It is formally defined in Table 10.

Table 10 – ExtrusionTemperatureZonesType Definition
Attribute Value
BrowseNameExtrusionTemperatureZonesType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC 10000-5
0:HasPropertyVariable0:NodeVersion0:String0:PropertyTypeM, RO
0:HasComponentObjectStartTempering3:StartDeviceTypeO
0:HasComponentObjectMaintenance3:MaintenanceTypeO
0:HasComponentObjectTemperatureZone_<Nr>

ExtrusionTemperature

ZoneType

OP
0:GeneratesEventObjectType0:GeneralModelChange
EventType

When instances for temperature zones are created, the BrowseNames shall be “TemperatureZone_<Nr>” where <Nr> is a three-digit number with leading zeros, starting with “001”. The ExtrusionTemperatureZoneType is defined in Table 11.

StartTempering: Main switch for all temperature zones in the container. The single zones have own switches/status AND-connection!

8.2 ExtrusionTemperatureZoneType

This ObjectType represents one temperature zone inside of a component of an extrusion line. It is formally defined in Table 11.

Table 11 – ExtrusionTemperatureZoneType Definition
Attribute Value
BrowseNameExtrusionTemperatureZoneType
IsAbstractFalse
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 3:MeasuringDeviceType defined in OPC 40083
0:HasComponentVariableNominalHeatingPower0:Double0:AnalogUnitTypeO, RO
0:HasComponentVariableNominalCoolingPower0:Double0:AnalogUnitTypeO, RO
0:HasComponentVariableControllerOutput0:Double0:AnalogUnitTypeO, RO
0:HasComponentObjectElectricalCurrent3:MonitoredParameterTypeO

8.2.1 NominalHeatingPower

Indication of the nominal heating power of the zone in kW. If the zone is only a cooling zone, this variable is not used.

8.2.2 NominalCoolingPower

Indication of the nominal cooling power of the zone in kW. If the zone is only a heating zone, this variable is not used.

8.2.3 ControllerOutput

Actual ratio of the used nominal power in %. Values from -100 (=max. cooling) to +100 (max. heating).

8.2.4 ElectricalCurrent

Actual electrical current of the zone in A.