7 OPC UA ObjectTypes ToC Previous Next

7.44 InletConnectionSystemRequirementsType ObjectType Definition ToC Previous Next

The InletConnectionSystemRequirementsType provides static Variables for Pump inlet connection specific parameters of the process in which the Pump is to be used and is formally defined in Table 96.

Table 96 – InletConnectionSystemRequirementsType Definition

Attribute Value        
BrowseName InletConnectionSystemRequirementsType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.          
0:HasComponent Variable InletPressure 0:Double 0:BaseAnalogType O, RW

The InstanceDeclarations of the InletConnectionSystemRequirementsType have additional Attributes defined in Table 97. The Variables and the associated Descriptions are based on the standard DIN ISO 21360-1.

Table 97 – InletConnectionSystemRequirementsType Attribute values for child Nodes

BrowsePath Value Attribute Description Attribute
InletPressure   Pressure at the inlet of the pump, measured at a defined location in the test dome.
   InletPressure
   0:EngineeringUnits
NamespaceUri: http://www.opcfoundation.org/UA/units/un/cefact
UnitId: 5259596
DisplayName: Pa
Description: pascal
 

Previous Next