7 OPC UA ObjectTypes ToC Previous Next

7.17 SupervisionAuxiliaryDeviceType ObjectType Definition ToC Previous Next

The SupervisionAuxiliaryDeviceType provides Variables used for monitoring the Pump auxiliary devices. It is formally defined in Table 41. For the generation of events, the SupervisionAuxiliaryDeviceType has references to the four Namur NE 107 statuses defined in OPC 10000-100. The InputNode Property of the Alarm shall contain the NodeId of the Component.

Table 41 – SupervisionAuxiliaryDeviceType Definition

Attribute Value        
BrowseName SupervisionAuxiliaryDeviceType        
IsAbstract false        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of the 2:FunctionalGroupType defined in OPC 10000-100, i.e. inheriting the InstanceDeclarations of that Node.          
0:HasComponent Variable ActuatorElement 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable AmbientTemperature 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable AuxiliaryDeviceFault 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable AuxiliaryMediumAbsence 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable AuxiliaryMediumInsufficiency 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable AuxiliaryPowerPole 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable AuxiliaryPowerRange 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable CommunicationError 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable Corrosion 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable Deviation 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable ElectromagneticInterference 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable ElectronicFault 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable EnergySupply 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable EvaluationElectronics 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable ExciterError 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable Fouling 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable HumidityElectronics 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable Installation 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable Interruption 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable LineLength 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable MaterialElectronics 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable MeasuredMaterialElectronics 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable MechanicalDamage 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable OperatingConditions 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable Other 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable Overloading 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable ParameterSetting 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable Peripheral 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable ProcessInfluence 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable SensorElement 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable StartUp 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable TemperatureShock 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable Vibration 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable WearReserveOperation 0:Boolean 0:TwoStateDiscreteType O, RO
0:HasComponent Variable WearReserveWear 0:Boolean 0:TwoStateDiscreteType O, RO
0:GeneratesEvent ObjectType 2:CheckFunctionAlarmType Defined in OPC 10000-100    
0:GeneratesEvent ObjectType 2:FailureAlarmType Defined in OPC 10000-100    
0:GeneratesEvent ObjectType 2:MaintenanceRequiredAlarmType Defined in OPC 10000-100    
0:GeneratesEvent ObjectType 2:OffSpecAlarmType Defined in OPC 10000-100    

The InstanceDeclarations of the SupervisionAuxiliaryDeviceType have additional Attributes defined in Table 42. The Variables and the associated Descriptions are based on the standard VDMA 24223-1.

Table 42 – SupervisionAuxiliaryDeviceType Attribute values for child Nodes

BrowsePath Description Attribute
ActuatorElement This property indicates a fault in an actuator element.
AmbientTemperature This property indicates an abnormal ambient temperature.
AuxiliaryDeviceFault This property indicates a generic failure of an auxiliary device.
AuxiliaryMediumAbsence This property indicates an absence of or wrong auxiliary medium.
AuxiliaryMediumInsufficiency This property indicates an insufficiency of auxiliary medium.
AuxiliaryPowerPole This property indicates an auxiliary power supply wrongly poled.
AuxiliaryPowerRange This property indicates an off-spec of the auxiliary power range.
CommunicationError This property indicates a communication error.
Corrosion This property indicates corrosion/abrasion in parts in contact with medium.
Deviation This property indicates an inadmissible deviation from measurement.
ElectromagneticInterference This property indicates an abnormal electromagnetic interference.
ElectronicFault This property indicates a fault in the device electronics.
EnergySupply This property indicates an error in internal energy supply.
EvaluationElectronics This property indicates an error in evaluation electronics.
ExciterError This property indicates an error in the exciter of the sensor element.
Fouling This property indicates a fouling on sensor element.
HumidityElectronics This property indicates an abnormal amount of humidity in electronics area.
Installation This property indicates an installation fault.
Interruption This property indicates an interruption of signal path or short circuit.
LineLength This property indicates that the maximum line length is exceeded.
MaterialElectronics This property indicates a foreign material in electronics area.
MeasuredMaterialElectronics This property indicates measured material in electronics area.
MechanicalDamage This property indicates a mechanical damage.
OperatingConditions This property indicates a fault due to non-compliance with specified operating conditions.
Other This property indicates other faults.
Overloading This property indicates an overloading.
ParameterSetting This property indicates a parameter setting error.
Peripheral This property indicates an error in peripherals.
ProcessInfluence This property indicates a fault due to process influence.
SensorElement This property indicates a fault in a sensor element.
StartUp This property indicate an installation fault or fault during start-up.
TemperatureShock This property indicates an excessive temperature shock.
Vibration This property indicates an excessive vibration or impact load.
WearReserveOperation This property indicates that the wear reserve is used up by operation.
WearReserveWear This property indicates that the wear reserve is used up by wear.

Previous Next