6 HRD_InterfaceType ToC Previous Next

6.1 HRD_InterfaceType Definition ToC Previous Next

This OPC UA ObjectType is used for the root Object representing a hot runner device with its subcomponents. It is formally defined inTable 1.

NOTE: To promote interoperability of Clients and Servers, all instantiated Devices shall be aggregated in an Object called “DeviceSet” (see OPC UA for Devices)

readme_files/image005.gif Figure 1 – HRD_InterfaceType Overview

Table 1 – HRD_InterfaceType Definition

Attribute Value        
BrowseName HRD_InterfaceType        
IsAbstract False        
References Node Class BrowseName DataType TypeDefinition Other
Subtype of 0:BaseObjectType defined in OPC UA Part 5          
0:HasComponent Object Identification   3:IdentificationType M
0:HasComponent Object MachineConfiguration   3:MachineConfigurationType M
0:HasComponent Object Operation   OperationType M
0:HasComponent Object Zones   ZonesType M
0:HasComponent Object Diagnostics   3:DiagnosticsType O
0:HasComponent Object MaintenanceInformation   MaintenanceInformationType O
0:HasProperty Variable DisplayLanguage 0:LocaleId 0:PropertyType O, RW
0:GeneratesEvent ObjectType 3:HelpOffNormalAlarmType Defined in OPC 40083    

The BrowseName of the object instance shall be “HRD_<Manufacturer>_<SerialNumber>”

Example: “HRD_Gammaflux_0123456”.

NOTE: The namespace of this BrowseName is the local server URI with namespace index 1 or a vendor specific namespace with server specific namespace index (see Table 29). The BrowseNames of the nodes below are in the namespace of the specification where used Type is defined.

Examples:

BrowseName Namespace Namespace index Remarks
HRD_Inglass_0123456 Local Server URI or vendor specific namespace 1 or server specific OPC 40082-2 only defines the HRD_InterfaceType. The instance is generated in the local server
(      
Identification http://opcfoundation.org/UA/PlasticsRubber/HotRunner/ server specific The object Identification is a child of HRD_InterfaceType which is defined in OPC 40082-2
(      
Manufacturer http://opcfoundation.org/UA/DI/ server specific The variable Manufacturer is a child of IdentificationType which is defined in OPC 40083. However, it derives from the ComponentType defined in OPC 10000-100. The Variable Manufacturer is defined there.
BrowseName Namespace Namespace index Remarks
HRD_Inglass_0123456 Local Server URI or vendor specific namespace 1 or server specific OPC 40082-2 only defines the HRD_InterfaceType. The instance is generated in the local server
(      
Zones http://opcfoundation.org/UA/PlasticsRubber/HotRunner/ server specific The object Zones is a child of HRD_InterfaceType which is defined in OPC 40082-2
(      
Zone_1 Local Server URI or vendor specific namespace 1 or server specific The objects for the zones are modelled as OptionalPlaceholder. The instances are server specific
(      
Temperature http://opcfoundation.org/UA/PlasticsRubber/HotRunner/ server specific The object Temperature is a child of ZoneType which is defined in OPC 40082-2
(      
ActualValue http://opcfoundation.org/UA/ PlasticsRubber/GeneralTypes/ server specific The variable ActualValue is a child of Temperature which has the HRDTemperatureType as type definition. This is derived from the ControlledParameterType which is defined in OPC 40083
BrowseName Namespace Namespace index Remarks
HRD_Inglass_0123456 Local Server URI or vendor specific namespace 1 or server specific OPC 40082-2 only defines the HRD_InterfaceType. The instance is generated in the local server
(      
Zones http://opcfoundation.org/UA/ PlasticsRubber/HotRunner/ server specific The object Zones is a child of HRD_InterfaceType which is defined in OPC 40082-2
(      
NodeVersion http://opcfoundation.org/UA/ 0 The Property NodeVersion is defined in OPC UA

Previous Next