This OPC UA ObjectType is used for the root Object representing a hot runner device with its subcomponents. It is formally defined inTable 1.

NOTE: To promote interoperability of Clients and Servers, all instantiated Devices shall be aggregated in an Object called “DeviceSet” (see OPC UA for Devices)

image006.gif

Figure 1 – HRD_InterfaceType Overview

Table 1 – HRD_InterfaceType Definition

Attribute

Value

BrowseName

HRD_InterfaceType

IsAbstract

False

References

Node Class

BrowseName

DataType

TypeDefinition

Other

Subtype of 0:BaseObjectType defined in OPC UA Part 5

0:HasComponent

Object

Identification

3:IdentificationType

M

0:HasComponent

Object

MachineConfiguration

3:MachineConfigurationType

M

0:HasComponent

Object

Operation

OperationType

M

0:HasComponent

Object

Zones

ZonesType

M

0:HasComponent

Object

Diagnostics

3:DiagnosticsType

O

0:HasComponent

Object

MaintenanceInformation

MaintenanceInformationType

O

0:HasProperty

Variable

DisplayLanguage

0:LocaleId

0:PropertyType

O, RW

0:GeneratesEvent

ObjectType

3:HelpOffNormalAlarmType

Defined in OPC 40083

The BrowseName of the object instance shall be "HRD_<Manufacturer>_<SerialNumber>"

Example: "HRD_Gammaflux_0123456".

NOTE: The namespace of this BrowseName is the local server URI with namespace index 1 or a vendor specific namespace with server specific namespace index (see Table 29). The BrowseNames of the nodes below are in the namespace of the specification where used Type is defined.

Examples:

BrowseName

Namespace

Namespace index

Remarks

HRD_Inglass_0123456

Local Server URI or vendor specific namespace

1 or server specific

OPC 40082-2 only defines the HRD_InterfaceType. The instance is generated in the local server

Identification

http://opcfoundation.org/UA/PlasticsRubber/HotRunner/

server specific

The object Identification is a child of HRD_InterfaceType which is defined in OPC 40082-2

Manufacturer

http://opcfoundation.org/UA/DI/

server specific

The variable Manufacturer is a child of IdentificationType which is defined in OPC 40083. However, it derives from the ComponentType defined in OPC 10000-100. The Variable Manufacturer is defined there.

BrowseName

Namespace

Namespace index

Remarks

HRD_Inglass_0123456

Local Server URI or vendor specific namespace

1 or server specific

OPC 40082-2 only defines the HRD_InterfaceType. The instance is generated in the local server

Zones

http://opcfoundation.org/UA/PlasticsRubber/HotRunner/

server specific

The object Zones is a child of HRD_InterfaceType which is defined in OPC 40082-2

Zone_1

Local Server URI or vendor specific namespace

1 or server specific

The objects for the zones are modelled as OptionalPlaceholder. The instances are server specific

Temperature

http://opcfoundation.org/UA/PlasticsRubber/HotRunner/

server specific

The object Temperature is a child of ZoneType which is defined in OPC 40082-2

ActualValue

http://opcfoundation.org/UA/PlasticsRubber/GeneralTypes/

server specific

The variable ActualValue is a child of Temperature which has the HRDTemperatureType as type definition. This is derived from the ControlledParameterType which is defined in OPC 40083

BrowseName

Namespace

Namespace index

Remarks

HRD_Inglass_0123456

Local Server URI or vendor specific namespace

1 or server specific

OPC 40082-2 only defines the HRD_InterfaceType. The instance is generated in the local server

Zones

http://opcfoundation.org/UA/PlasticsRubber/HotRunner/

server specific

The object Zones is a child of HRD_InterfaceType which is defined in OPC 40082-2

NodeVersion

http://opcfoundation.org/UA/

0

The Property NodeVersion is defined in OPC UA