7 Type definitions for Frying Pan ToC Previous Next

7.2 FryingPanParameterType ToC Previous Next

7.2.3 Description of the object type ToC Previous Next

7.2.3.1 ProgramMode variable ToC

This variable describes the state of the device, e.g. heating up or frying.

The data type for the FryingPanModeEnumeration is defined in section 7.4.1.

7.2.3.2 CookingLevel variable ToC

This variable describes the cooking level with which heating up is to take place.

The value is used only in the Cook and CookSlow ProgramMode.

7.2.3.3 SetTemperature variable ToC

This variable contains the set temperature to which heating up is to take place. With pressure cooking the set pressure is calculated on the basis of the set temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

7.2.3.4 ActualTemperatur variable ToC

This variable describes the currently measured temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

7.2.3.5 SetProcessTime variable ToC

This variable describes the set process time in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

7.2.3.6 TimeRemaining variable ToC

This variable describes the remaining process time in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

7.2.3.7 SetCoreTemperature variable ToC

This variable describes the set core temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

7.2.3.8 ActualCoreTemperature variable ToC

This variable describes the currently measured core temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

7.2.3.9 SignalMode variable ToC

This variable describes the state of the signal output. In addition to the on and off states, the “Signal was acknowledged” state is also saved.

The data type for the SignalModeEnumeration is defined in 7.4.2.

7.2.3.10 ActualPressurePan variable ToC

This variable describes the currently measured pressure in the pan.

The EngineeringUnit property of the AnalogItemType has the value mbar. The value for the EURange property is device-specific.

7.2.3.11 IsLidLocked variable ToC

This variable describes whether the lid is locked.

Previous Next