16 Type definitions for Servery System ToC Previous Next

16.2 TrayType ToC Previous Next

16.2.2 Description of the object type ToC Previous Next

16.2.2.1 ProgramMode variable ToC

Represents the current operation mode.

The data type for the TrayModeEnumeration is defined in 16.4.1.

16.2.2.2 ActualTemperature variable ToC

This variable contains the currently measured temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

16.2.2.3 SetTemperature variable ToC

This variable contains the set temperature.

The EngineeringUnit property of the AnalogItemType has the value C. The value for the EURange property is device-specific.

16.2.2.4 Name variable ToC

Specifies a free-text designation for the tray.

16.2.2.5 Type variable ToC

This variable represents the tray type.

The data type for the TrayModeEnumeration is defined in 16.4.2.

16.2.2.6 ActiveSince variable ToC

Indicates the time in seconds since the start of the current operating state. If no valid count can be specified for the current state, the value -1 is signalled.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

16.2.2.7 OperatingCounter variable ToC

This variable describes the accumulated operating time in seconds.

The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.

Previous Next