Represents the current operation mode.
The data type for the TrayModeEnumeration is defined in 16.4.1.
This variable contains the currently measured temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
This variable contains the set temperature.
The EngineeringUnit property of the AnalogItemType has the value °C. The value for the EURange property is device-specific.
Specifies a free-text designation for the tray.
This variable represents the tray type.
The data type for the TrayModeEnumeration is defined in 16.4.2.
Indicates the time in seconds since the start of the current operating state. If no valid count can be specified for the current state, the value -1 is signalled.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.
This variable describes the accumulated operating time in seconds.
The EngineeringUnit property of the AnalogItemType has the value s. The value for the EURange property is device-specific.