Search
3 result(s) for safety function response time
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety3.1.1.10 safety function response timesafety function response time worst case elapsed time following an actuation of a safety sensor connected to a fieldbus, until the corresponding safe state of its safety actuator ... achieved in the presence of errors or failures in the safety function Note 1 to entry: This concept is introduced in IEC 61784‑3:2021, 5.2.4 and is addressed
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safetymaximum time between two executions of the SafetyConsumer will contribute to the safety function response time ( SFRT ). Some safety functions, such as the transfer of safe configuration data at startup
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetySafety function response time part of communication For cyclic communication, the part of the safety function response time attributable to a safety communication according to this document (SFRTOPCSafety) is specified ... Calculation of safety function response time part of OPC UA safety SFRTOPCSafety <= 2 × SafetyConsumerTimeout + ConsumerCycleTime (1) where SFRTOPCSafety: Part of the safety function response time attributable to the safety