5 result(s) for revisedSamplingInterval
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.1.2 Sampling intervalServer specifies a value for the MinimumSamplingInterval Attribute it shall always return a revisedSamplingInterval that is equal or higher than the MinimumSamplingInterval if the Client subscribes to the Value Attribute
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.2.2 Parametersfactors, including capabilities of the underlying system. The Server shall always return a revisedSamplingInterval that is equal or higher than the requested samplingInterval . If the requested samplingInterval is higher than
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.3.1 DescriptionThey take effect as soon as practical but not later than twice the new revisedSamplingInterval . The return diagnostic info setting in the request header of the CreateMonitoredItems or the last
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.3.2 Parametersfactors, including capabilities of the underlying system. The Server shall always return a revisedSamplingInterval that is equal or higher than the requested samplingInterval . If the requested samplingInterval is higher than
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.21 MonitoringParameterssampling interval that it supports. The assigned interval is provided in the revisedSamplingInterval parameter. The Server shall always return a revisedSamplingInterval that is equal or higher than the requested samplingInterval