Search
6 result(s) for interval
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates3.1.3 EffectiveEndTimesometimes necessary to return an Interpolated End Bound as the value for an Interval with a timestamp that is in the interval . Servers are expected to use the time immediately
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.2.4 Time calculation issuessometimes necessary to return an Interpolated End Bound as the value for an Interval with a timestamp that is in the Interval . Servers are expected to use the time immediately ... Server determines the exact value. If there is one data point in the Interval and it falls on the StartTime the time duration used in calculations is one unit
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.6 TimeAveragefind the value of a point at the beginning and end of an interval. Starting at the starting bounding value a straight line is drawn between each value ... interval ending at the ending bounding value (see examples for illustrations). The area under the lines is divided by the length of the ProcessingInterval to yield the average. Note that
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network ModelHasComponent Variable MaxIntervalFrames UInt16 BaseDataVariableType Mandatory HasComponent Variable MaxFrameSize UInt32 BaseDataVariableType Mandatory HasComponent Variable Interval UnsignedRationalNumber BaseDataVariableType Mandatory Conformance Units BNM TSN Config The MaxFrameSize of DataType UInt16 specifies ... UInt16 Variable specifies the maximum number of frames that will be sent during an Interval. (as defined in IEEE 802.1Q-2018 , clause 35.2.2.8.4b, "MaxIntervalFrames" or IEEE
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions25.6 ResetReset This Method sets the RemainingInterval to Interval and Status to NOT_DUE_0. Signature Reset (); The method has no Input - or OutputArguments . Table 138 - Reset Method AddressSpace Definition Attribute
-
OPC-40444 – OPC UA for Textile Testing DevicesHasComponent Variable Activity 0:LocalizedText 0:BaseDataVariableType M 0:HasProperty Variable Interval 0:UtcTime 0:PropertyType O 0:HasProperty Variable LastExecutionTime 0:UtcTime 0:PropertyType M Conformance Units TTD_RecurrentPrognosisType ... Activity is a localized text message specifying the task that is to be performed. Interval represents the normal (estimated) time period between two task executions. LastExecutionTime is the last time